Re: [PATCH V1] ARM: dts: am335x-bone-common: Increase MDIO reset deassert time

From: Kevin Hilman
Date: Mon Jul 08 2024 - 20:05:03 EST



On Fri, 31 May 2024 13:38:17 -0500, Colin Foster wrote:
> Prior to commit df16c1c51d81 ("net: phy: mdio_device: Reset device only
> when necessary") MDIO reset deasserts were performed twice during boot.
> Now that the second deassert is no longer performed, device probe
> failures happen due to the change in timing with the following error
> message:
>
> SMSC LAN8710/LAN8720: probe of 4a101000.mdio:00 failed with error -5
>
> [...]

Applied, thanks!

[1/1] ARM: dts: am335x-bone-common: Increase MDIO reset deassert time
commit: b9e33fd0c6f8a29643d3b6ec149d2a7693cbe902

Best regards,
--
Kevin Hilman <khilman@xxxxxxxxxxxx>