[PATCH v5 5.10/5.15] ata: libata-scsi: check cdb length for VARIABLE_LENGTH_CMD commands

From: Artem Sadovnikov
Date: Thu Jul 11 2024 - 11:16:07 EST


Fuzzing of 5.10 stable branch reports a slab-out-of-bounds error in
ata_scsi_pass_thru.

The error is fixed in 5.18 by commit ce70fd9a551a ("scsi: core: Remove the
cmd field from struct scsi_request") upstream.

The problem is that the length of the received SCSI command is not
validated if scsi_op == VARIABLE_LENGTH_CMD. It can lead to out-of-bounds
reading if the user sends a request with SCSI command of length less than
32.

Found by Linux Verification Center (linuxtesting.org) with Syzkaller.

Signed-off-by: Artem Sadovnikov <ancowi69@xxxxxxxxx>
Signed-off-by: Mikhail Ivanov <iwanov-23@xxxxx>
Signed-off-by: Mikhail Ukhin <mish.uxin2012@xxxxxxxxx>
---
drivers/ata/libata-scsi.c | 3 +++
1 file changed, 3 insertions(+)

diff --git a/drivers/ata/libata-scsi.c b/drivers/ata/libata-scsi.c
index 36f32fa052df..4397986db053 100644
--- a/drivers/ata/libata-scsi.c
+++ b/drivers/ata/libata-scsi.c
@@ -3949,6 +3949,9 @@ static unsigned int ata_scsi_var_len_cdb_xlat(struct ata_queued_cmd *qc)
const u8 *cdb = scmd->cmnd;
const u16 sa = get_unaligned_be16(&cdb[8]);

+ if (scmd->cmd_len != 32)
+ return 1;
+
/*
* if service action represents a ata pass-thru(32) command,
* then pass it to ata_scsi_pass_thru handler.
--
2.34.1