[PATCH v1 02/10] iio: pressure: bmp280: Fix waiting time for BMP3xx configuration
From: Vasileios Amoiridis
Date: Thu Jul 11 2024 - 17:16:53 EST
According to the datasheet, both pressure and temperature can go up to
oversampling x32. With this option, the maximum measurement time is not
80ms (this is for press x32 and temp x2), but it is 130ms nominal
(calculated from table 3.9.2) and since most of the maximum values
are around +15%, it is configured to 150ms.
Fixes: 8d329309184d ("iio: pressure: bmp280: Add support for BMP380 sensor family")
Signed-off-by: Vasileios Amoiridis <vassilisamir@xxxxxxxxx>
---
drivers/iio/pressure/bmp280-core.c | 7 ++++---
1 file changed, 4 insertions(+), 3 deletions(-)
diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c
index cc8553177977..3deaa57bb3f5 100644
--- a/drivers/iio/pressure/bmp280-core.c
+++ b/drivers/iio/pressure/bmp280-core.c
@@ -1581,10 +1581,11 @@ static int bmp380_chip_config(struct bmp280_data *data)
}
/*
* Waits for measurement before checking configuration error
- * flag. Selected longest measure time indicated in
- * section 3.9.1 in the datasheet.
+ * flag. Selected longest measurement time, calculated from
+ * formula in datasheet section 3.9.2 with an offset of ~+15%
+ * as it seen as well in table 3.9.1.
*/
- msleep(80);
+ msleep(150);
/* Check config error flag */
ret = regmap_read(data->regmap, BMP380_REG_ERROR, &tmp);
--
2.25.1