Say there are 3 trip points A, B, C sorted in ascending temperature
order with no hysteresis. If the zone temerature is exactly equal to
B, thermal_zone_set_trips() will set the boundaries to A and C and the
hardware will not catch any crossing of B (either way) until either A
or C is crossed and the boundaries are changed.
To avoid that, use non-strict inequalities when comparing the trip
threshold to the zone temperature in thermal_zone_set_trips().
In the example above, it will cause both boundaries to be set to B,
which is desirable because an interrupt will trigger when the zone
temperature becomes different from B regardless of which way it goes.
That will allow a new interval to be set depending on the direction of
the zone temperature change.
Fixes: 893bae92237d ("thermal: trip: Make thermal_zone_set_trips() use trip thresholds")
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@xxxxxxxxx>
---
6.11-rc material.
---
drivers/thermal/thermal_trip.c | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)
Index: linux-pm/drivers/thermal/thermal_trip.c
===================================================================
--- linux-pm.orig/drivers/thermal/thermal_trip.c
+++ linux-pm/drivers/thermal/thermal_trip.c
@@ -82,10 +82,10 @@ void thermal_zone_set_trips(struct therm
return;
for_each_trip_desc(tz, td) {
- if (td->threshold < tz->temperature && td->threshold > low)
+ if (td->threshold <= tz->temperature && td->threshold > low)
low = td->threshold;
- if (td->threshold > tz->temperature && td->threshold < high)
+ if (td->threshold >= tz->temperature && td->threshold < high)
high = td->threshold;
}