There are two minor issues regarding this function.
One is that it attempts to calculate the second calibration value even
if 1-point trimming is being used; in this case, the calculated value is
probably not useful and is never used anyway. Changing this also
requires a minor reordering in Exynos5433 initialization function, so
that we know which type of trimming is used before we call
sanitize_temp_error.
The second issue is that the function is not very consistent when it
comes to the use of Exynos7-specific parameters. This seems to not be an
issue in practice, in part because some of these issues are related to
the mentioned calculation of the second calibration value. However,
fixing this makes the code a bit less confusing, and will be required
for Exynos850 which has 9-bit temperature values and uses 2-point
trimming.
Reviewed-by: Sam Protsenko <semen.protsenko@xxxxxxxxxx>
Signed-off-by: Mateusz Majewski <m.majewski2@xxxxxxxxxxx>
---
v1 -> v2: reworked to change shift instead of only mask and to also fix
the 2-point trimming issue.
drivers/thermal/samsung/exynos_tmu.c | 23 ++++++++++++++---------
1 file changed, 14 insertions(+), 9 deletions(-)
diff --git a/drivers/thermal/samsung/exynos_tmu.c b/drivers/thermal/samsung/exynos_tmu.c
index b68e9755c933..087a09628e23 100644
--- a/drivers/thermal/samsung/exynos_tmu.c
+++ b/drivers/thermal/samsung/exynos_tmu.c
@@ -111,6 +111,7 @@
#define EXYNOS7_TMU_REG_EMUL_CON 0x160
#define EXYNOS7_TMU_TEMP_MASK 0x1ff
+#define EXYNOS7_TMU_TEMP_SHIFT 9
#define EXYNOS7_PD_DET_EN_SHIFT 23
#define EXYNOS7_TMU_INTEN_RISE0_SHIFT 0
#define EXYNOS7_EMUL_DATA_SHIFT 7
@@ -234,20 +235,23 @@ static void sanitize_temp_error(struct exynos_tmu_data *data, u32 trim_info)
u16 tmu_temp_mask =
(data->soc == SOC_ARCH_EXYNOS7) ? EXYNOS7_TMU_TEMP_MASK
: EXYNOS_TMU_TEMP_MASK;
+ int tmu_85_shift =
+ (data->soc == SOC_ARCH_EXYNOS7) ? EXYNOS7_TMU_TEMP_SHIFT
+ : EXYNOS_TRIMINFO_85_SHIFT;
data->temp_error1 = trim_info & tmu_temp_mask;
- data->temp_error2 = ((trim_info >> EXYNOS_TRIMINFO_85_SHIFT) &
- EXYNOS_TMU_TEMP_MASK);
-
if (!data->temp_error1 ||
(data->min_efuse_value > data->temp_error1) ||
(data->temp_error1 > data->max_efuse_value))
- data->temp_error1 = data->efuse_value & EXYNOS_TMU_TEMP_MASK;
+ data->temp_error1 = data->efuse_value & tmu_temp_mask;
- if (!data->temp_error2)
- data->temp_error2 =
- (data->efuse_value >> EXYNOS_TRIMINFO_85_SHIFT) &
- EXYNOS_TMU_TEMP_MASK;
+ if (data->cal_type == TYPE_TWO_POINT_TRIMMING) {
+ data->temp_error2 = (trim_info >> tmu_85_shift) & tmu_temp_mask;
+ if (!data->temp_error2)
+ data->temp_error2 =
+ (data->efuse_value >> tmu_85_shift) &
+ tmu_temp_mask;
+ }
}
static int exynos_tmu_initialize(struct platform_device *pdev)
@@ -510,7 +514,6 @@ static void exynos5433_tmu_initialize(struct platform_device *pdev)
int sensor_id, cal_type;
trim_info = readl(data->base + EXYNOS_TMU_REG_TRIMINFO);
- sanitize_temp_error(data, trim_info);
/* Read the temperature sensor id */
sensor_id = (trim_info & EXYNOS5433_TRIMINFO_SENSOR_ID_MASK)
@@ -532,6 +535,8 @@ static void exynos5433_tmu_initialize(struct platform_device *pdev)
break;
}
+ sanitize_temp_error(data, trim_info);
+
dev_info(&pdev->dev, "Calibration type is %d-point calibration\n",
cal_type ? 2 : 1);
}