Re: [PATCH v2 1/5] dt-bindings: remoteproc: sse710: Add the External Systems remote processors
From: Abdellatif El Khlifi
Date: Fri Sep 20 2024 - 10:20:23 EST
Hi Krzysztof,
> >>>>> + '#extsys-id':
> >>>>
> >>>> '#' is not correct for sure, that's not a cell specifier.
> >>>>
> >>>> But anyway, we do not accept in general instance IDs.
> >>>
> >>> I'm happy to replace the instance ID with another solution.
> >>> In our case the remoteproc instance does not have a base address
> >>> to use. So, we can't put remoteproc@address
> >>>
> >>> What do you recommend in this case please ?
> >>
> >> Waiting one month to respond is a great way to drop all context from my
> >> memory. The emails are not even available for me - gone from inbox.
> >>
> >> Bus addressing could note it. Or you have different devices, so
> >> different compatibles. Tricky to say, because you did not describe the
> >> hardware really and it's one month later...
> >>
> >
> > Sorry for waiting. I was in holidays.
> >
> > I'll add more documentation about the external system for more clarity [1].
> >
> > Basically, Linux runs on the Cortex-A35. The External system is a
> > Cortex-M core. The Cortex-A35 can not access the memory of the Cortex-M.
> > It can only control Cortex-M core using the reset control and status registers mapped
> > in the memory space of the Cortex-A35.
>
> That's pretty standard.
>
> It does not explain me why bus addressing or different compatible are
> not sufficient here.
Using an instance ID was a design choice.
I'm happy to replace it with the use of compatible and match data (WIP).
The match data will be pointing to a data structure containing the right offsets
to be used with regmap APIs.
syscon node is used to represent the Host Base System Control register area [1]
where the external system reset registers are mapped (EXT_SYS*).
The nodes will look like this:
syscon@1a010000 {
compatible = "arm,sse710-host-base-sysctrl", "simple-mfd", "syscon";
reg = <0x1a010000 0x1000>;
#address-cells = <1>;
#size-cells = <1>;
remoteproc@310 {
compatible = "arm,sse710-extsys0";
reg = <0x310 4>;
...
}
remoteproc@318 {
compatible = "arm,sse710-extsys1";
reg = <0x318 4>;
...
}
[1]: https://developer.arm.com/documentation/102342/0000/Programmers-model/Register-descriptions/Host-Base-System-Control-register-summary
Cheers
Abdellatif