Re: [PATCH] HID: wacom: Hardcode (non-inverted) AES pens as BTN_TOOL_PEN
From: Benjamin Tissoires
Date: Wed Oct 09 2024 - 12:16:52 EST
On Oct 08 2024, Gerecke, Jason wrote:
> From: Jason Gerecke <jason.gerecke@xxxxxxxxx>
>
> Unlike EMR tools which encode type information in their tool ID, tools
> for AES sensors are all "generic pens". It is inappropriate to make use
> of the wacom_intuos_get_tool_type function when dealing with these kinds
> of devices. Instead, we should only ever report BTN_TOOL_PEN or
> BTN_TOOL_RUBBER, as depending on the state of the Eraser and Invert
> bits.
>
> Fixes: 9c2913b962da ("HID: wacom: more appropriate tool type categorization")
> Signed-off-by: Jason Gerecke <jason.gerecke@xxxxxxxxx>
> Cc: stable@xxxxxxxxxxxxxxx
Thanks for the quick fix Jason.
You are however missing a few links/reported-by:
Reported-by: Daniel Jutz <daniel@xxxxxxxxx>
Closes: https://lore.kernel.org/linux-input/3cd82004-c5b8-4f2a-9a3b-d88d855c65e4@xxxxxxxxx/
Bisected-by: Christian Heusel <christian@xxxxxxxxx>
Link: https://gitlab.freedesktop.org/libinput/libinput/-/issues/1041
Link: https://github.com/linuxwacom/input-wacom/issues/440
Acked-by: Benjamin Tissoires <bentiss@xxxxxxxxxx>
Hopefully with the above b4 would pick those out without having to send
a v2.
Cheers,
Benjamin
> ---
> drivers/hid/wacom_wac.c | 2 ++
> 1 file changed, 2 insertions(+)
>
> diff --git a/drivers/hid/wacom_wac.c b/drivers/hid/wacom_wac.c
> index 59a13ad9371cd..413606bdf476d 100644
> --- a/drivers/hid/wacom_wac.c
> +++ b/drivers/hid/wacom_wac.c
> @@ -2567,6 +2567,8 @@ static void wacom_wac_pen_report(struct hid_device *hdev,
> /* Going into range select tool */
> if (wacom_wac->hid_data.invert_state)
> wacom_wac->tool[0] = BTN_TOOL_RUBBER;
> + else if (wacom_wac->features.quirks & WACOM_QUIRK_AESPEN)
> + wacom_wac->tool[0] = BTN_TOOL_PEN;
> else if (wacom_wac->id[0])
> wacom_wac->tool[0] = wacom_intuos_get_tool_type(wacom_wac->id[0]);
> else
> --
> 2.46.2
>