Re: [PATCH v1 09/13] iio: chemical: bme680: Move ambient temperature to attributes
From: Andy Shevchenko
Date: Fri Oct 11 2024 - 06:12:37 EST
On Thu, Oct 10, 2024 at 11:00:26PM +0200, vamoirid wrote:
> From: Vasileios Amoiridis <vassilisamir@xxxxxxxxx>
>
> Remove the ambient temperature from being a macro and implement it as
> an attribute. This way, it is possible to dynamically configure the
> ambient temperature of the environment to improve the accuracy of the
> measurements.
...
> - var1 = (((s32)BME680_AMB_TEMP * calib->par_gh3) / 1000) * 256;
> + var1 = (((s32)data->ambient_temp * calib->par_gh3) / 1000) * 256;
MILLI? KILO?
...
> static struct attribute *bme680_attributes[] = {
> &iio_const_attr_oversampling_ratio_available.dev_attr.attr,
> + &iio_dev_attr_ambient_temp.dev_attr.attr,
> NULL,
Side note: Perhaps a patch or an additional change in the existing one to drop
the trailing comma here.
> };
--
With Best Regards,
Andy Shevchenko