[PATCH 12/31] s390/ap_bus: Switch to use hrtimer_setup()
From: Nam Cao
Date: Mon Oct 28 2024 - 03:37:22 EST
There is a newly introduced hrtimer_setup() which will replace
hrtimer_init(). This new function is similar to the old one, except that it
also sanity-checks and initializes the timer's callback function.
Switch to use this new function.
Patch was created by using Coccinelle.
Signed-off-by: Nam Cao <namcao@xxxxxxxxxxxxx>
---
Cc: Christian Borntraeger <borntraeger@xxxxxxxxxxxxx>
---
drivers/s390/crypto/ap_bus.c | 3 +--
1 file changed, 1 insertion(+), 2 deletions(-)
diff --git a/drivers/s390/crypto/ap_bus.c b/drivers/s390/crypto/ap_bus.c
index 60cea6c24349..98beb2656c3f 100644
--- a/drivers/s390/crypto/ap_bus.c
+++ b/drivers/s390/crypto/ap_bus.c
@@ -2327,8 +2327,7 @@ static inline int __init ap_async_init(void)
*/
if (MACHINE_IS_VM)
poll_high_timeout = 1500000;
- hrtimer_init(&ap_poll_timer, CLOCK_MONOTONIC, HRTIMER_MODE_ABS);
- ap_poll_timer.function = ap_poll_timeout;
+ hrtimer_setup(&ap_poll_timer, ap_poll_timeout, CLOCK_MONOTONIC, HRTIMER_MODE_ABS);
queue_work(system_long_wq, &ap_scan_bus_work);
--
2.39.5