On 24/11/2024 02:41, Krishna Chaitanya Chundru wrote:The axi clock frequency internal to the switch, host can't control
...framework to control the clocks. For this switch there are no clocks needs to be control, the moment we power on the switch clocks are enabled by default. This switch provides a mechanism to control the frequency using i2c. And switch supports only two frequencies i.e
+ qps615,axi-clk-freq-hz:
That's a downstream code you send us.
Anyway, why assigned clock rates do not work for you? You are re-implementing legacy property now under different name :/
The assigned clock rates comes in to the picture when we are using clock
frequency of what, since there are no clocks?
125MHz and 250MHZ by default it runs on 250MHz, we can do one i2c write with which switch runs in 125MHz.
How doing a write is relevant? Or you want to say you can control clock?
Best regards, Krzysztof