Re: [PATCH] iio: ABI: combine current input sections
From: Jonathan Cameron
Date: Fri Dec 20 2024 - 15:09:45 EST
On Thu, 19 Dec 2024 13:25:23 -0600
David Lechner <dlechner@xxxxxxxxxxxx> wrote:
> Combine two duplicate sections describing in_currentY_raw.
>
> This went unnoticed until we renamed in_currentX_raw to in_currentY_raw
> and the kernel test robot found the duplication.
>
> Reported-by: kernel test robot <lkp@xxxxxxxxx>
> Closes: https://lore.kernel.org/oe-kbuild-all/202412200256.OB5Hmw5Q-lkp@xxxxxxxxx/
> Signed-off-by: David Lechner <dlechner@xxxxxxxxxxxx>
Applied.
Thanks,
J
> ---
> Documentation/ABI/testing/sysfs-bus-iio | 19 +++++--------------
> 1 file changed, 5 insertions(+), 14 deletions(-)
>
> diff --git a/Documentation/ABI/testing/sysfs-bus-iio b/Documentation/ABI/testing/sysfs-bus-iio
> index d97c35057a034c76ed433e3e6de0aff8ec4bbb70..25d366d452a55293c420300335a0271a28855107 100644
> --- a/Documentation/ABI/testing/sysfs-bus-iio
> +++ b/Documentation/ABI/testing/sysfs-bus-iio
> @@ -168,18 +168,6 @@ Description:
> is required is a consistent labeling. Units after application
> of scale and offset are millivolts.
>
> -What: /sys/bus/iio/devices/iio:deviceX/in_currentY_raw
> -What: /sys/bus/iio/devices/iio:deviceX/in_currentY_supply_raw
> -KernelVersion: 3.17
> -Contact: linux-iio@xxxxxxxxxxxxxxx
> -Description:
> - Raw (unscaled no bias removal etc.) current measurement from
> - channel Y. In special cases where the channel does not
> - correspond to externally available input one of the named
> - versions may be used. The number must always be specified and
> - unique to allow association with event codes. Units after
> - application of scale and offset are milliamps.
> -
> What: /sys/bus/iio/devices/iio:deviceX/in_powerY_raw
> KernelVersion: 4.5
> Contact: linux-iio@xxxxxxxxxxxxxxx
> @@ -1700,15 +1688,18 @@ Description:
> or without compensation from tilt sensors.
>
> What: /sys/bus/iio/devices/iio:deviceX/in_currentY_raw
> +What: /sys/bus/iio/devices/iio:deviceX/in_currentY_supply_raw
> What: /sys/bus/iio/devices/iio:deviceX/in_currentY_i_raw
> What: /sys/bus/iio/devices/iio:deviceX/in_currentY_q_raw
> -KernelVersion: 3.18
> +KernelVersion: 3.17
> Contact: linux-iio@xxxxxxxxxxxxxxx
> Description:
> Raw current measurement from channel Y. Units are in milliamps
> after application of scale and offset. If no offset or scale is
> present, output should be considered as processed with the
> - unit in milliamps.
> + unit in milliamps. In special cases where the channel does not
> + correspond to externally available input one of the named
> + versions may be used.
>
> Channels with 'i' and 'q' modifiers always exist in pairs and both
> channels refer to the same signal. The 'i' channel contains the in-phase
>
> ---
> base-commit: fe2a04fbcbfe44694fcb36ff6212fce54b8f56cc
> change-id: 20241219-iio-abi-combine-current-input-sections-c62cf5dbfa9b
>
> Best regards,