Re: [PATCH net-next 0/2] net: phy: dp83822: Add support for changing the transmit amplitude voltage

From: Dimitri Fedrau
Date: Mon Jan 13 2025 - 09:18:44 EST


Hi Andrew,

Am Mon, Jan 13, 2025 at 02:54:28PM +0100 schrieb Andrew Lunn:
> On Mon, Jan 13, 2025 at 06:40:11AM +0100, Dimitri Fedrau via B4 Relay wrote:
> > Add support for changing the transmit amplitude voltage in 100BASE-TX mode.
> > Add support for configuration via DT.
>
> The commit message is supposed to answer the question "Why?". Isn't
> reducing the voltage going to make the device non conforming? Why
> would i want to break it? I could understand setting it a bit higher
> than required to handle losses on the PCB and connector, so the
> voltages measured on the RJ45 pins are conforming.
>
- Will add the "Why?" to the commit description. You already answered it.
- Yes you are right.
- I don't want to break it, the PHY just provides these settings. And I
just wanted to reflect this in the code, although it probably doesn't
make sense.
- In my case I want to set it a bit higher to be conforming.

> Also, what makes the dp8382 special? I know other PHYs can actually do
> this. So why are we adding some vendor specific property just for
> 100base-tx?
>
I don't think that the dp83822 is special in this case. I just didn't
know better. Would be removing the vendor specific property enough ?
Or is there already a defined property describing this. Didn't found
anything.

Best regards,
Dimitri