[PATCH 1/2] staging: gpib: Add missing interface entry point

From: Dave Penkler
Date: Wed Jan 22 2025 - 05:39:26 EST


Declaring the driver entry points as static caused a warning
that the serial_poll_status function of the agilent_82350b driver
was unused.

Add the entry point to the corresponding interface structure
initializations where it was missing.

Fixes: 09a4655ee1eb ("staging: gpib: Add HP/Agilent/Keysight 8235xx PCI GPIB driver")
Signed-off-by: Dave Penkler <dpenkler@xxxxxxxxx>
---
drivers/staging/gpib/agilent_82350b/agilent_82350b.c | 2 ++
1 file changed, 2 insertions(+)

diff --git a/drivers/staging/gpib/agilent_82350b/agilent_82350b.c b/drivers/staging/gpib/agilent_82350b/agilent_82350b.c
index 0ba592dc9849..cd7fe7d814ce 100644
--- a/drivers/staging/gpib/agilent_82350b/agilent_82350b.c
+++ b/drivers/staging/gpib/agilent_82350b/agilent_82350b.c
@@ -842,6 +842,7 @@ static gpib_interface_t agilent_82350b_unaccel_interface = {
.primary_address = agilent_82350b_primary_address,
.secondary_address = agilent_82350b_secondary_address,
.serial_poll_response = agilent_82350b_serial_poll_response,
+ .serial_poll_status = agilent_82350b_serial_poll_status,
.t1_delay = agilent_82350b_t1_delay,
.return_to_local = agilent_82350b_return_to_local,
};
@@ -869,6 +870,7 @@ static gpib_interface_t agilent_82350b_interface = {
.primary_address = agilent_82350b_primary_address,
.secondary_address = agilent_82350b_secondary_address,
.serial_poll_response = agilent_82350b_serial_poll_response,
+ .serial_poll_status = agilent_82350b_serial_poll_status,
.t1_delay = agilent_82350b_t1_delay,
.return_to_local = agilent_82350b_return_to_local,
};
--
2.47.1