On Wed, 12 Feb 2025 at 12:54, Krzysztof Kozlowski <krzk@xxxxxxxxxx> wrote:Hi, in hardware, the SM8650's DP controller supports 2 INTFs, while the QCS8300's DP0 controller supports 4 INTFs.In sst mode, only one INTF will be used, they are same, but for MST, sm8650 supports 2 streams while qcs8300 support 4 streams. Thanks.
On 12/02/2025 11:41, Dmitry Baryshkov wrote:
On Wed, Feb 12, 2025 at 03:12:24PM +0800, Yongxing Mou wrote:So the original patch was probably correct...
We need to enable mst for qcs8300, dp0 controller will support 2 streams
output. So not reuse sm8650 dp controller driver and will add a new driver
patch for qcs8300 mst feature. Modify the corresponding dt-bingding file
to compatible with the qcs8300-dp.
NAK for a different reason: QCS8300 is still compatible with SM8650.
Enable features instead of randomly reshuffle compats. In this case,
enable MST for both architectures.
I have no idea. I'd let Yongxing Mou to comment on this. It would be
nice instead of getting a lengthy explanation of obvious items to get
an answer to an actual question: is QCS8300 compatible with SM8650 or
not. In other words whether they can support the same number of MST
streams on each controller or not.