Re: [PATCH 2/2] net: phy: marvell-88q2xxx: Prevent reading temperature with asserted reset

From: Dimitri Fedrau
Date: Wed Feb 19 2025 - 05:56:04 EST


Hi Stefan,

Am Wed, Feb 19, 2025 at 07:29:49AM +0100 schrieb Stefan Eichenberger:
> Hi Dimitri,
>
> On Tue, Feb 18, 2025 at 07:33:10PM +0100, Dimitri Fedrau wrote:
> > If the PHYs reset is asserted it returns 0xffff for any read operation.
> > Prevent reading the temperature in this case and return with an I/O error.
> > Write operations are ignored by the device.
> >
> > Fixes: a197004cf3c2 ("net: phy: marvell-88q2xxx: Fix temperature measurement with reset-gpios")
> > Signed-off-by: Dimitri Fedrau <dima.fedrau@xxxxxxxxx>
> > ---
> > drivers/net/phy/marvell-88q2xxx.c | 6 ++++++
> > 1 file changed, 6 insertions(+)
> >
> > diff --git a/drivers/net/phy/marvell-88q2xxx.c b/drivers/net/phy/marvell-88q2xxx.c
> > index 30d71bfc365597d77c34c48f05390db9d63c4af4..c1ae27057ee34feacb31c2e3c40b2b1769596408 100644
> > --- a/drivers/net/phy/marvell-88q2xxx.c
> > +++ b/drivers/net/phy/marvell-88q2xxx.c
> > @@ -647,6 +647,12 @@ static int mv88q2xxx_hwmon_read(struct device *dev,
> > struct phy_device *phydev = dev_get_drvdata(dev);
> > int ret;
> >
> > + /* If the PHYs reset is asserted it returns 0xffff for any read
> > + * operation. Return with an I/O error in this case.
> > + */
> > + if (phydev->mdio.reset_state == 1)
> > + return -EIO;
> > +
> > switch (attr) {
> > case hwmon_temp_input:
> > ret = phy_read_mmd(phydev, MDIO_MMD_PCS,
> >
>
> It makes sense to me. However, aren't most phys that allow reading
> sensors over MDIO affected by this issue? I couldn't find anything
> similar, are they ignoring that use-case?
>
Yes, you are right, but only if the PHYs hard reset is controlled with
"reset-gpios" or similar. I didn't find anything about it too.

Best regards,
Dimitri Fedrau