Re: [PATCH 14/14] Documentation: ABI: testing: ad4080 docs

From: Nuno Sá
Date: Thu Feb 20 2025 - 09:54:20 EST


On Thu, 2025-02-20 at 15:54 +0200, Antoniu Miclaus wrote:
> Add documentation for the ad4080 attributes.
>
> Signed-off-by: Antoniu Miclaus <antoniu.miclaus@xxxxxxxxxx>
> ---
>  .../ABI/testing/sysfs-bus-iio-adc-ad4080      | 55 +++++++++++++++++++
>  1 file changed, 55 insertions(+)
>  create mode 100644 Documentation/ABI/testing/sysfs-bus-iio-adc-ad4080
>
> diff --git a/Documentation/ABI/testing/sysfs-bus-iio-adc-ad4080
> b/Documentation/ABI/testing/sysfs-bus-iio-adc-ad4080
> new file mode 100644
> index 000000000000..e37bfba0e989
> --- /dev/null
> +++ b/Documentation/ABI/testing/sysfs-bus-iio-adc-ad4080
> @@ -0,0 +1,55 @@
> +What: /sys/bus/iio/devices/iio:deviceX/lvds_sync
> +Date: February 2025
> +KernelVersion:
> +Contact: linux-iio@xxxxxxxxxxxxxxx
> +Description:
> + This attribute handles the data synchronization
> process.Because the CNV
> + signal is not taken into account by the FPGA when capturing
> the data, we
> + need a process that configures the ADC to output pattern
> data, writes the
> + SYNC bit in the axi_adc register map, waits until the custom
> HDL syncs the
> + data correctly, and then changes the output mode to analog
> data instead of
> + the fixed pattern.

I'll comment this one in the driver. I have some questions on how this works...

> +
> +What: /sys/bus/iio/devices/iio:deviceX/lvds_lvds
> +Date: February 2025
> +KernelVersion:
> +Contact: linux-iio@xxxxxxxxxxxxxxx
> +Description:
> + Configures the signal type of the CNV signal. The value can
> be either CMOS
> + (lvds_cnv=0) or LVDS (lvds_cnv=1).

The name seems to be wrong with what you have implemented. From this
description, I would think of this as a DT property? Can the signal type really
change at runtime?

> +
> +What: /sys/bus/iio/devices/iio:deviceX/filter_sel
> +Date: February 2025
> +KernelVersion:
> +Contact: linux-iio@xxxxxxxxxxxxxxx
> +Description:
> + This attribute enables the digital filter functionality of
> the AD4080.In
> + order to capture data correctly, the function must configure
> the ADC
> + through SPI to select the filter type and enable data capture
> in filter
> + mode through axi_adc(In this mode, data is gated by a signal
> generated by
> + the AD4080 (GPIO1 and is not continuous as it is when the
> filter is
> + disabled).
> +
> +What: /sys/bus/iio/devices/iio:deviceX/filter_sel_available
> +Date: February 2025
> +KernelVersion:
> +Contact: linux-iio@xxxxxxxxxxxxxxx
> +Description:
> + Return the available filter modes that can be set.

There's a standard attr for this. I think we settled
> +
> +What: /sys/bus/iio/devices/iio:deviceX/sinc_dec_rate
> +Date: February 2025
> +KernelVersion:
> +Contact: linux-iio@xxxxxxxxxxxxxxx
> +Description:
> + Set the filter’s decimation rate.
> +
> +What: /sys/bus/iio/devices/iio:deviceX/sinc_dec_rate_available
> +Date: February 2025
> +KernelVersion:
> +Contact: linux-iio@xxxxxxxxxxxxxxx
> +Description:
> + Return the available filter's decimation rates.
> +
> +

I'm not yet convinced we need the dec_rate custom attr. I'll add more comments
in the driver.

- Nuno Sá