Re: [PATCH 1/5] dt-bindings: display: mediatek: mdp-rsz: Add rules for MT8196
From: Sunny Shen (沈姍姍)
Date: Sun Feb 23 2025 - 12:50:09 EST
On Tue, 2025-02-11 at 17:54 +0000, Conor Dooley wrote:
> On Tue, Feb 11, 2025 at 10:52:50AM +0800, Sunny Shen wrote:
> > Add MDP-RSZ hardware description for MediaTek MT8196 SoC
> >
> > Signed-off-by: Sunny Shen <sunny.shen@xxxxxxxxxxxx>
> > ---
> > .../display/mediatek/mediatek,mdp-rsz.yaml | 46
> > +++++++++++++++++++
> > 1 file changed, 46 insertions(+)
> > create mode 100644
> > Documentation/devicetree/bindings/display/mediatek/mediatek,mdp-
> > rsz.yaml
> >
> > diff --git
> > a/Documentation/devicetree/bindings/display/mediatek/mediatek,mdp-
> > rsz.yaml
> > b/Documentation/devicetree/bindings/display/mediatek/mediatek,mdp-
> > rsz.yaml
> > new file mode 100644
> > index 000000000000..6642b9aa651a
> > --- /dev/null
> > +++
> > b/Documentation/devicetree/bindings/display/mediatek/mediatek,mdp-
> > rsz.yaml
> > @@ -0,0 +1,46 @@
> > +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
> > +%YAML 1.2
> > +---
> > +$id:
> > http://devicetree.org/schemas/display/mediatek/mediatek,mdp-rsz.yaml#
>
> Filename matching compatible please
Got it
will modify the compatible to "mediatek,mt8196-mdp-rsz"
>
> > +$schema: http://devicetree.org/meta-schemas/core.yaml#
> > +
> > +title: MediaTek display multimedia data path resizer
> > +
> > +maintainers:
> > + - Chun-Kuang Hu <chunkuang.hu@xxxxxxxxxx>
> > + - Philipp Zabel <p.zabel@xxxxxxxxxxxxxx>
> > +
> > +description: |
> > + MediaTek display multimedia data path resizer, namely MDP-RSZ,
> > + can do scaling up/down to the picture.
> > +
> > +properties:
> > + compatible:
> > + const: mediatek,mt8196-disp-mdp-rsz
> > +
> > + reg:
> > + maxItems: 1
> > +
> > + clocks:
> > + items:
> > + - description: MDP-RSZ Clock
>
> This can just be "maxItems: 1"
OK, will modify this
>
> > +
> > +required:
> > + - compatible
> > + - reg
> > + - clocks
> > +
> > +additionalProperties: false
> > +
> > +examples:
> > + - |
> > + soc {
> > + #address-cells = <2>;
> > + #size-cells = <2>;
> > +
> > + disp_mdp_rsz0: disp-mdp-rsz0@321a0000 {
>
> And "disp-mdp-rsz0" isn't anything close to a generic node name.
Will modify "disp-mdp-rsz0@321a0000" to "mdp-rsz@321a0000"
>
> > + compatible = "mediatek,mt8196-disp-mdp-rsz";
> > + reg = <0 0x321a0000 0 0x1000>;
> > + clocks = <&dispsys_config_clk 101>;
>
> Surprised there are so few properties, no ports link or anything like
> that?
Because the mt8196's path mux design, we use mdp-rsz as a bypass mode
hw.
So only set the basic properties.
>
> > + };
> > + };
> > --
> > 2.34.1
> >