RE: [PATCH] Remove some PMU events for FUJITSU-MONAKA
From: Yoshihiro Furudera (Fujitsu)
Date: Wed Mar 05 2025 - 01:41:59 EST
Hi, James
>
> Hi, James
> Thank you for your comment.
>
> > On 27/02/2025 5:40 am, Yoshihiro Furudera wrote:
> > > The following events are not counted properly:
> > >
> > > 0x0037 LL_CACHE_MISS_RD
> > > 0x400B L3D_CACHE_LMISS_RD
> >
> > These two are discoverable so will still appear in
> > /sys/bus/event_source/devices/armv8_pmuv3_0/events/ if the hardware
> > says they exist. It might be better to change the json strings of
> > these two to warn that they don't work if that's the case, otherwise
> > Perf will still list them and you'll be worse off.
>
> I will leave these 2 events and
> add a warning message to the description in the JSON file.
> I will handle other events in the same way as these 2 events.
I'm thinking of adding one of the following warnings
to the description of events where inaccurate counts
occur on FUJITSU-MONAKA.
Is this okay?
1.Simple version
"Note: This event does not count accurately."
2.Detailed version
"Note: This event does not count accurately because it counts as a miss regardless of whether the L3 prefetch is a hit or miss."
I think "2.Detailed version" is better.
example:
{
"EventCode": "0x0396",
"EventName": "L2D_CACHE_REFILL_L3D_MISS",
"BriefDescription": "This event counts operations that cause a miss of the L3 cache. Note: This event does not count accurately because it counts as a miss regardless of whether the L3 prefetch is a hit or miss."
}
Best Regards,
Yoshihiro Furudera