[PATCH v3 4/7] Input: synaptics-rmi4 - f55: handle zero electrode count

From: David Heidelberg via B4 Relay
Date: Sat Mar 08 2025 - 09:09:13 EST


From: methanal <baclofen@xxxxxxx>

Some third party ICs claim to support f55 but report an electrode count
of 0. Catch this and bail out early so that we don't confuse the i2c bus
with 0 sized reads.

Signed-off-by: methanal <baclofen@xxxxxxx>
[simplify code, adjust wording]
Signed-off-by: Caleb Connolly <caleb.connolly@xxxxxxxxxx>
---
drivers/input/rmi4/rmi_f55.c | 5 +++++
1 file changed, 5 insertions(+)

diff --git a/drivers/input/rmi4/rmi_f55.c b/drivers/input/rmi4/rmi_f55.c
index 488adaca4dd00482cd1106d813b32871092c83a0..ad2ef14ae9f4e897473db43334792cc3de966d52 100644
--- a/drivers/input/rmi4/rmi_f55.c
+++ b/drivers/input/rmi4/rmi_f55.c
@@ -52,6 +52,11 @@ static int rmi_f55_detect(struct rmi_function *fn)

f55->num_rx_electrodes = f55->qry[F55_NUM_RX_OFFSET];
f55->num_tx_electrodes = f55->qry[F55_NUM_TX_OFFSET];
+ if (!f55->num_rx_electrodes || !f55->num_tx_electrodes) {
+ rmi_dbg(RMI_DEBUG_FN, &fn->dev,
+ "F55 query returned no electrodes, giving up\n");
+ return 0;
+ }

f55->cfg_num_rx_electrodes = f55->num_rx_electrodes;
f55->cfg_num_tx_electrodes = f55->num_rx_electrodes;

--
2.47.2