[PATCH v4 3/4] drivers/thermal/exymos: Fixed the efuse min max value for exynos5422
From: Anand Moon
Date: Mon Mar 10 2025 - 10:36:08 EST
As per Exynos5422 user manual e-Fuse range min~max range is 16~76.
if e-Fuse value is out of this range, then thermal sensor may not
sense thermal data properly. Refactors the efuse value
initialization logic within exynos_map_dt_data function by
replacing the nested if-else statements with a switch statement.
Ensures proper initialization of efuse values based on the SOC type.
Signed-off-by: Anand Moon <linux.amoon@xxxxxxxxx>
---
drivers/thermal/samsung/exynos_tmu.c | 19 +++++++++++++++----
1 file changed, 15 insertions(+), 4 deletions(-)
diff --git a/drivers/thermal/samsung/exynos_tmu.c b/drivers/thermal/samsung/exynos_tmu.c
index ac3b9d2c900ca..a71cde0a4b17e 100644
--- a/drivers/thermal/samsung/exynos_tmu.c
+++ b/drivers/thermal/samsung/exynos_tmu.c
@@ -899,12 +899,23 @@ static int exynos_map_dt_data(struct platform_device *pdev)
data->gain = 8;
data->reference_voltage = 16;
data->efuse_value = 55;
- if (data->soc != SOC_ARCH_EXYNOS5420 &&
- data->soc != SOC_ARCH_EXYNOS5420_TRIMINFO)
+ data->max_efuse_value = 100;
+ switch (data->soc) {
+ case SOC_ARCH_EXYNOS3250:
+ case SOC_ARCH_EXYNOS4412:
+ case SOC_ARCH_EXYNOS5250:
+ case SOC_ARCH_EXYNOS5260:
data->min_efuse_value = 40;
- else
+ break;
+ case SOC_ARCH_EXYNOS5420:
+ case SOC_ARCH_EXYNOS5420_TRIMINFO:
+ data->min_efuse_value = 16;
+ data->max_efuse_value = 76;
+ break;
+ default:
data->min_efuse_value = 0;
- data->max_efuse_value = 100;
+ break;
+ }
break;
case SOC_ARCH_EXYNOS5433:
data->tmu_set_low_temp = exynos5433_tmu_set_low_temp;
--
2.48.1