Re: [PATCH v2 2/2] iio: humditiy: hdc3020: fix units for thresholds and hysteresis

From: Andy Shevchenko
Date: Tue Sep 02 2025 - 08:48:52 EST


On Mon, Sep 01, 2025 at 07:51:59PM +0200, Dimitri Fedrau via B4 Relay wrote:
> From: Dimitri Fedrau <dimitri.fedrau@xxxxxxxxxxxx>
>
> According to the ABI the units after application of scale and offset are
> milli degree celsius for temperature thresholds and milli percent for
> relative humidity thresholds. Currently the resulting units are degree
> celsius for temperature thresholds and hysteresis and percent for relative
> humidity thresholds and hysteresis. Change scale factor to fix this issue.

...

> /*
> - * Get the temperature threshold from 9 LSBs, shift them to get
> - * the truncated temperature threshold representation and
> - * calculate the threshold according to the formula in the
> - * datasheet. Result is degree celsius scaled by 65535.
> + * Get the temperature threshold from 9 LSBs, shift them to get the
> + * truncated temperature threshold representation and calculate the
> + * threshold according to the formula in the datasheet and additionally

Replace "formula in the datasheet" by explicit formula

> + * scale by HDC3020_THRESH_FRACTION to avoid precision loss when
> + * calculating threshold and hysteresis values.
> */
> temp = FIELD_GET(HDC3020_THRESH_TEMP_MASK, thresh) <<
> HDC3020_THRESH_TEMP_TRUNC_SHIFT;
>
> - return -2949075 + (175 * temp);
> + return -589815 + (35 * temp);

TBH, I prefer to have the proper units be mentioned in the comment along with

return -2949075 / 5 + ((175 / 5) * temp);

5 itself can be a definition

#define ..._PRE_SCALE 5

and used everywhere.

...

> /*
> * Get the humidity threshold from 7 MSBs, shift them to get the
> * truncated humidity threshold representation and calculate the
> - * threshold according to the formula in the datasheet. Result is
> - * percent scaled by 65535.
> + * threshold according to the formula in the datasheet and additionally
> + * scale by HDC3020_THRESH_FRACTION to avoid precision loss when
> + * calculating threshold and hysteresis values.
> */

Ditto. "percent scaled by ..." is much better to understand.

> hum = FIELD_GET(HDC3020_THRESH_HUM_MASK, thresh) <<
> HDC3020_THRESH_HUM_TRUNC_SHIFT;
>
> - return hum * 100;
> + return hum * 20;
> }

--
With Best Regards,