When the backend domain crashes, coordinated device cleanup is not
possible (as it involves waiting for the backend state change). In that
case, toolstack forcefully removes frontend xenstore entries.
xenbus_dev_changed() handles this case, and triggers device cleanup.
It's possible that toolstack manages to connect new device in that
place, before xenbus_dev_changed() notices the old one is missing. If
that happens, new one won't be probed and will forever remain in
XenbusStateInitialising.
Fix this by checking backend-id and if it changes, consider it
unplug+plug operation. It's important that cleanup on such unplug
doesn't modify xenstore entries (especially the "state" key) as it
belong to the new device to be probed - changing it would derail
establishing connection to the new backend (most likely, closing the
device before it was even connected). Handle this case by setting new
xenbus_device->vanished flag to true, and check it before changing state
entry.
And even if xenbus_dev_changed() correctly detects the device was
forcefully removed, the cleanup handling is still racy. Since this whole
handling doesn't happend in a single xenstore transaction, it's possible
that toolstack might put a new device there already. Avoid re-creating
the state key (which in the case of loosing the race would actually
close newly attached device).
The problem does not apply to frontend domain crash, as this case
involves coordinated cleanup.
Problem originally reported at
https://lore.kernel.org/xen-devel/aOZvivyZ9YhVWDLN@mail-itl/T/#t,
including reproduction steps.
Signed-off-by: Marek Marczykowski-Górecki <marmarek@xxxxxxxxxxxxxxxxxxxxxx>
Attachment:
OpenPGP_0xB0DE9DD628BF132F.asc
Description: OpenPGP public key