Re: [PATCH 2/2] iio: accel: adxl380: Add support for 1 kHz sampling frequency

From: Francesco Lavra

Date: Thu Jan 08 2026 - 10:56:37 EST


On Thu, 2026-01-08 at 13:45 +0000, Nuno Sá wrote:
> On Wed, 2026-01-07 at 16:39 +0100, Francesco Lavra wrote:
> > On Wed, 2026-01-07 at 13:56 +0000, Nuno Sá wrote:
> >
> > > 3. Other thing that comes to mind is if it makes sense to allow
> > > controlling odr if
> > > Activity/Inactivity detection is enabled?
> >
> > Disallowing odr control when activity detection is enabled could be an
> > option, but what error code should be returned if the user tries to set
> > the
> > sampling frequency value when not allowed? -EBUSY?
>
> I think it makes sense given the constrains on activity events. EBUSY
> would be my choice as well.
> Out of curiosity, do you know how the chip behaves if we change the odr
> with activity enabled? Is it
> just ignored?

The chip supports activity detection only when in low-power mode; changing
the odr to a value that requires exiting from low-power mode would mean
effectively disabling activity detection. The driver prevents this by
forcing low-power mode whenever detection is enabled, which means that any
odr changes by userspace do not take effect as long as detection is
enabled.

Attachment: signature.asc
Description: This is a digitally signed message part