Re: [PATCH 1/3] dt-bindings: arm: mediatek: mmsys: Allow single vdo/mmsys endpoint

From: AngeloGioacchino Del Regno

Date: Wed Jan 14 2026 - 03:27:38 EST


Il 13/01/26 23:53, Rob Herring ha scritto:
On Thu, Jan 08, 2026 at 03:39:32PM +0100, AngeloGioacchino Del Regno wrote:
The hardware supports using just a single output while leaving all
of the others unconfigured (disabled), but the binding did not
really allow specifying a single endpoint@0, because in this case
one must either:
- Call the subnode `endpoint` and not declare any address and/or
size cells; or
- Call the subnode `endpoint@0` and have at least one more other
endpoint(@1 or @2), and declare address/size cells.

Allow specifying a single `endpoint` subnode, without the `@0`
implicit suffix to suppress warnings happening on this kind of
valid usecase.

This series isn't needed. We've dropped this check from dtc. I'll do a
sync with upstream.

In any case, it's also a W=1 warning which wouldn't be my top priority.

Rob

Oh, okay! Thanks for the feedback :D

Cheers,
Angelo