Re: [PATCH v2 1/2] dt-bindings: ethernet: eswin: add clock sampling control

From: Andrew Lunn

Date: Mon Feb 09 2026 - 08:25:20 EST


> The rx-internal-delay-ps and tx-internal-delay-ps properties now use
> minimum and maximum constraints to reflect the actual hardware delay
> range (0-2400 ps) applied in 20 ps steps.


> rx-internal-delay-ps:
> - enum: [0, 200, 600, 1200, 1600, 1800, 2000, 2200, 2400]
> + minimum: 0
> + maximum: 2400

multipleOf: 20

Also, 2400 / 20 = 120. Is the real maximum 127 * 20 = 2540?

> @@ -111,17 +129,44 @@ examples:
> interrupts = <61>;
> interrupt-names = "macirq";
> phy-mode = "rgmii-id";
> - phy-handle = <&phy0>;
> + phy-handle = <&gmac0_phy0>;
> resets = <&reset 95>;
> reset-names = "stmmaceth";
> + rx-internal-delay-ps = <20>;
> + tx-internal-delay-ps = <100>;

I would not include them in the example. You are going to get
developers blindly copying this into real DT. A well designed board
should not need delays.

Andrew