Re: [PATCH v7 2/3] dt-bindings: hwmon: emc2305: Add fan-shutdown-percent property
From: Guenter Roeck
Date: Thu Apr 30 2026 - 19:14:29 EST
On Wed, Apr 29, 2026 at 09:59:54AM +0300, florin.leotescu@xxxxxxxxxxx wrote:
> From: Florin Leotescu <florin.leotescu@xxxxxxx>
>
> The EMC2305 fan controller supports multiple independent PWM fan
> outputs. Some systems require fans to enter a defined safe state
> during system shutdown or reboot handoff, until firmware or the next
> boot stage reconfigures the controller.
>
> Add an optional "fan-shutdown-percent" property to fan child nodes
> allowing the PWM duty cycle applied during shutdown to be configured
> per fan output.
>
> Signed-off-by: Florin Leotescu <florin.leotescu@xxxxxxx>
> Acked-by: Conor Dooley <conor.dooley@xxxxxxxxxxxxx>
Applied.
Thanks,
Guenter