Re: [PATCH v2] mfd: loongson-se: Add multi-node support

From: Qunqin Zhao

Date: Sun May 17 2026 - 23:22:54 EST



在 2026/4/27 下午6:02, Huacai Chen 写道:
On Mon, Apr 27, 2026 at 5:52 PM Qunqin Zhao <zhaoqunqin@xxxxxxxxxxx> wrote:

在 2026/4/27 下午5:37, Huacai Chen 写道:
On Mon, Apr 27, 2026 at 5:24 PM Qunqin Zhao <zhaoqunqin@xxxxxxxxxxx> wrote:
在 2026/4/27 下午5:02, Huacai Chen 写道:
Hi, Qunqin,

On Mon, Apr 27, 2026 at 4:55 PM Qunqin Zhao <zhaoqunqin@xxxxxxxxxxx> wrote:
On the Loongson platform, each node is equipped with a security engine
device. However, due to a hardware flaw, only the device on node 0 can
trigger interrupts. Therefore, interrupts from other nodes are forwarded
by node 0. We need to check in the interrupt handler of node 0 whether
this interrupt is intended for other nodes.
Multi-node or multi-package? In my opinion SE has no relationship with
NUMA node, so maybe package?
Here is the output of lscpu from my machine:

[loongson@localhost ~]$ lscpu
Architecture: loongarch64
CPU op-mode(s): 32-bit, 64-bit
Address sizes: 48 bits physical, 48 bits virtual
Byte Order: Little Endian
CPU(s): 128
On-line CPU(s) list: 0-127
Model name: Loongson-3C6000/D
CPU family: Loongson-64bit
Model: 0x11
Thread(s) per core: 2
Core(s) per socket: 32
Socket(s): 2
BogoMIPS: 4200.00
Flags: cpucfg lam ual fpu lsx lasx crc32 complex crypto
lvz lbt_x86 lbt_arm lbt_mips
Caches (sum of all):
L1d: 4 MiB (64 instances)
L1i: 4 MiB (64 instances)
L2: 16 MiB (64 instances)
L3: 128 MiB (4 instances)
NUMA:
NUMA node(s): 4
NUMA node0 CPU(s): 0-31
NUMA node1 CPU(s): 32-63
NUMA node2 CPU(s): 64-95
NUMA node3 CPU(s): 96-127

There are four SE devices in my system, one for each NUMA node.
For Loongson-3C6000 node is the same as package. You should consider
Loongson-3C5000L, one package contains four nodes.
I am not familiar with the SE-related components on the 3C5000L, and
this driver is not compatible with the 5000 series.
Whether it is compatible to Loongson-3C5000L is not important. The
importance is package is not always equal to node, and we should
consider whether SE is per-node or per-package.

Hi, huacai

After consulting with  hardware team, I learned that while the 3C5000L
has four SE devices, only one is utilized due to interrupt constraints.