[PATCH 3/8] dt-bindings: clock: clocking-wizard: Make s_axi_aclk optional for static-config

From: Shubhrajyoti Datta

Date: Sun Jun 14 2026 - 23:50:50 EST


In static-config mode the AXI bus interface is unused, so s_axi_aclk
is not required. Allow clocks/clock-names to have only one entry
(clk_in1) when xlnx,static-config is present and enforce two entries
otherwise. Update the static-config example accordingly.

Signed-off-by: Shubhrajyoti Datta <shubhrajyoti.datta@xxxxxxx>
---

.../bindings/clock/xlnx,clocking-wizard.yaml | 16 ++++++++++++++--
1 file changed, 14 insertions(+), 2 deletions(-)

diff --git a/Documentation/devicetree/bindings/clock/xlnx,clocking-wizard.yaml b/Documentation/devicetree/bindings/clock/xlnx,clocking-wizard.yaml
index aa397550d107..0daefe89ea89 100644
--- a/Documentation/devicetree/bindings/clock/xlnx,clocking-wizard.yaml
+++ b/Documentation/devicetree/bindings/clock/xlnx,clocking-wizard.yaml
@@ -29,11 +29,13 @@ properties:
const: 1

clocks:
+ minItems: 1
items:
- description: clock input
- description: axi clock

clock-names:
+ minItems: 1
items:
- const: clk_in1
- const: s_axi_aclk
@@ -87,9 +89,19 @@ allOf:
then:
required:
- xlnx,clk-mul-div
+ properties:
+ clocks:
+ maxItems: 1
+ clock-names:
+ maxItems: 1
else:
required:
- reg
+ properties:
+ clocks:
+ minItems: 2
+ clock-names:
+ minItems: 2

additionalProperties: false

@@ -109,8 +121,8 @@ examples:
clock-controller {
compatible = "xlnx,clocking-wizard";
#clock-cells = <1>;
- clocks = <&clkc 15>, <&clkc 18>;
- clock-names = "clk_in1", "s_axi_aclk";
+ clocks = <&clkc 15>;
+ clock-names = "clk_in1";
xlnx,nr-outputs = <6>;
xlnx,speed-grade = <1>;
xlnx,static-config;
--
2.49.1