Re: [PATCH] net: phy: marvell: Add soft reset for 88E1510
From: Andrew Lunn
Date: Fri Jul 03 2026 - 08:53:38 EST
On Fri, Jul 03, 2026 at 12:14:26AM +0000, Ben Brown wrote:
>
>
> On 7/3/26 11:04, Andrew Lunn wrote:
> > On Fri, Jul 03, 2026 at 10:50:34AM +1200, Ben Brown wrote:
> >> When bringing down then up the link on a 88e1512 phy a link is not
> >> getting established. This is because the phy is coming out of reset then
> >> immediately getting configured. During configuration the page is
> >> unsuccessfully updated causing writes to the wrong registers.
> >>
> >> Add the soft reset function that does a reset then polling read waiting
> >> for the phy to come back online, at which stage the page register can be
> >> updated successfully.
> >>
> >> This was tested on a 88E1512 phy, using ip link to bring up/down the
> >> link.
> >
> > What makes the 88E1512 special that it needs this, but no other
> > Marvell PHY does?
> >
> > Andrew
>
> This may be needed on the other marvell phys, but I only have access to
> a 88E1512 phy so I am only updating what I have seen this on.
The Marvell driver is used a lot, so i would of expected somebody else
to of noticed.
Lets take a step back.
What sort of reset are we talking about? Software or hardware?
Andrew