Re: [PATCH] drm/panel-edp: Add BOE NE140QDM-NX2

From: Weiji Wang

Date: Sat Jul 25 2026 - 16:58:40 EST


Hi,


On 7/26/26 00:29, Doug Anderson wrote:
Right that using the "enable" delay is more conservative, but it does
sound as if "prepare_to_enable" is more correct in this case if you
are provided "(T4+T5+T6+T8)-min".

I re-looked at the one panel using "delay_200_500_p2e80"
(NV116WHM-T01), since I still have access to that datasheet. There, I
see:

T4+T5+T6+T8 > 80ms
0ms < T7 <= 50ms
50ms < T8

In other words, T7-max is 50 and T8-min is 50.

Based on that, I believe it would be more correct for this panel to
use "delay_200_500_e50_p2e80". I'll try to send a patch for that,
which would get rid of the need for "delay_200_500_p2e80".

Does that match your panel, too?

-Doug


Yes, the constraints of T4+T5+T6+T8, T7 and T8 is exactly same as mine.
However, my copy of datasheet did not mention min/max value of T6, and it
feels like assuming T6-min=0 if setting 'enable' to 50ms, or
max(T7-max, T8-min). Is that proper?

Sorry to inconvenience you due to my inexperience in LCD panels.