Re: [PATCH v2 10/33] ibmvfc: add logic for protocol specific fabric logins
From: Dave Marquardt
Date: Wed Jul 29 2026 - 12:13:57 EST
Tyrel Datwyler <tyreld@xxxxxxxxxxxxx> writes:
> @@ -1530,8 +1538,14 @@ static void ibmvfc_set_login_info(struct ibmvfc_host *vhost)
> login_info->max_cmds = cpu_to_be32(max_cmds);
> login_info->capabilities = cpu_to_be64(IBMVFC_CAN_MIGRATE | IBMVFC_CAN_SEND_VF_WWPN);
>
> - if (vhost->mq_enabled || vhost->using_channels)
> + if (vhost->mq_enabled || vhost->using_channels) {
> login_info->capabilities |= cpu_to_be64(IBMVFC_CAN_USE_CHANNELS);
> + if (vhost->nvme_enabled) {
> + login_info->capabilities |= cpu_to_be64(IBMVFC_YES_NVMEOF);
> + login_info->capabilities |= cpu_to_be64(IBMVFC_YES_SCSI);
> + login_info->capabilities |= cpu_to_be64(IBMVFC_CAN_USE_WWPN_ALL);
> + }
> + }
Should setting IBMVFC_YES_SCSI be conditioned on vhost->nvme_enabled?
-Dave