[PATCH 0/5] iio: humidity: hts221: update probe and logging implementations
From: Adi Nata
Date: Sat Aug 08 2026 - 05:00:58 EST
HTS221 is an older driver. This series groups a few small modernizations
based on current development practices.
- Report available values via read_avail()
- Add a blank line after variable declarations (style)
- Allow unknown whoami for DT fallback instead of erroring out
- Use dev_err_probe() in probe paths
- Reject calibration data that would cause division by zero
No HTS221 hardware was available. Verified with checkpatch --strict and
builds of hts221, hts221_i2c and hts221_spi. Probe and calibration
error paths were exercised against i2c-stub with register contents
pre-loaded via i2cset.
Adi Nata (5):
iio: humidity: hts221: report available values via read_avail()
iio: humidity: hts221: Add a blank line after variable declarations
iio: humidity: hts221: Allow unknown whoami for DT fallback
iio: humidity: hts221: use dev_err_probe() in probe paths
iio: humidity: hts221: fix division by zero in calibration parsing
drivers/iio/humidity/hts221_buffer.c | 1 +
drivers/iio/humidity/hts221_core.c | 171 ++++++++++++---------------
drivers/iio/humidity/hts221_i2c.c | 8 +-
drivers/iio/humidity/hts221_spi.c | 8 +-
4 files changed, 85 insertions(+), 103 deletions(-)
--
2.47.3