Re: [PATCH v3] i2c: xiic: restore non-managed runtime PM to fix clk WARN flood
From: Andy Shevchenko
Date: Wed Aug 19 2026 - 02:48:59 EST
On Wed, Aug 19, 2026 at 09:45:41AM +0300, Andy Shevchenko wrote:
> On Tue, Aug 18, 2026 at 08:35:10AM -0700, Abdurrahman Hussain wrote:
...
> > pm_runtime_set_autosuspend_delay(dev, XIIC_PM_TIMEOUT);
> > pm_runtime_use_autosuspend(dev);
> > - ret = devm_pm_runtime_set_active_enabled(dev);
> > - if (ret)
> > - return ret;
> > + /*
> > + * Enable runtime PM by hand: devm_pm_runtime_set_active_enabled()
> > + * tears down in an order that races the devm-enabled clock release and
> > + * makes clk_core_disable() WARN (see xiic_i2c_remove()).
> > + */
> > + pm_runtime_set_active(dev);
> > + pm_runtime_enable(dev);
> >
> > /* SCL frequency configuration */
> > i2c->input_clk = clk_get_rate(i2c->clk);
>
> > ret = devm_request_threaded_irq(dev, irq, NULL, xiic_process,
> > IRQF_ONESHOT, pdev->name, i2c);
> > if (ret)
> > - return ret;
> > + goto err_pm_disable;
>
> This might be problematic now. You need to unwind the IRQ request in non-devm
> manner as well. Scenario is that IRQ comes exactly after PM is disabled
> in the error path. Is it a problem today? What about tomorrow (assuming some
> new chips / code is added)?
(To be clear: I'm talking about next call(s) that may fail, like xiic_reinit()
later in the probe.)
> The rule of thumb is that, no devm_*() call should be followed by a goto.
--
With Best Regards,
Andy Shevchenko