Re: [PATCH v2] dt-bindings: usb: qcom,snps-dwc3: Fix glymur binding for non-MP controllers
From: Krzysztof Kozlowski
Date: Thu Sep 03 2026 - 02:57:09 EST
On 02/09/2026 16:10, Konrad Dybcio wrote:
> On 8/31/26 2:29 PM, Krzysztof Kozlowski wrote:
>> On 31/08/2026 11:03, Krishna Kurapati wrote:
>>>
>>>
>>> On 8/31/2026 2:07 PM, Krzysztof Kozlowski wrote:
>>>> On Fri, Aug 28, 2026 at 01:45:42PM +0530, Krishna Kurapati wrote:
>>>>> Currently for Glymur non-multiport USB controllers, number of interrupts
>>>>> are limited to a maximum of "5". Either hs_phy_irq or ss_phy_irq are to be
>>>>> present.
>
> [...]
>
>>>>> - qcom,eliza-dwc3
>>>>> + - qcom,glymur-dwc3
>>>>> - qcom,ipq4019-dwc3
>>>>> - qcom,ipq8064-dwc3
>>>>> - qcom,kaanapali-dwc3
>>>>
>>>> This changes the ABI without an explanation.
>>>>
>>> As per the harware specification, the controllers do have both
>>> hs_phy_irq and ss_phy_irq. Hence wanted the binding to capture that
>>> info. Will update the commit message accordingly.
>>>
>>
>> So the change in 99df63d20dabda8d7ae01bcca7cdb1e92110a555 was
>> incomplete? Lack of context here is not helping.
>>
>> If they have these IRQs but it does not matter, then it is not a good
>> reason to change ABI and you should just add the clock as optional to
>> the end. Was this binding already released? I think yes.
>
> IIUC the intent of the patch is to allow specifying the currently
> missing hs_phy_irq on non-multiport controllers (i.e. usb3_[012]).
> Bundling the DT change would have made that easier.
This does not answer my concerns. So repeating: patch is changing ABI
without an explanation. This means contributor needs to provide
explanation for the ABI change in terms of actual impact.
Best regards,
Krzysztof