Re: [PATCH v2 2/3] interconnect: qcom: x1e80100: enable QoS configuration

From: Konrad Dybcio

Date: Mon Sep 07 2026 - 09:33:20 EST


On 9/7/26 10:49 AM, Marc Zyngier wrote:
> On Mon, 07 Sep 2026 09:18:38 +0100,
> Raviteja Laggyshetty <raviteja.laggyshetty@xxxxxxxxxxxxxxxx> wrote:
>>
>>
>>
>> On 9/7/2026 1:39 PM, Marc Zyngier wrote:
>>> On Wed, 02 Sep 2026 14:00:52 +0100,
>>> Mostafa Saleh <smostafa@xxxxxxxxxx> wrote:
>>>>
>>>> On Wed, May 27, 2026 at 05:37:10AM +0000, Raviteja Laggyshetty wrote:
>>>>> Enable QoS configuration for master ports with predefined priority
>>>>> and urgency forwarding.

[...]

>>> I'm also seeing spurious resets on my "X1E001DE Snapdragon Devkit for
>>> Windows" when doing large file transfers over the network (30GB+).
>>> With this patch reverted on top of 7.3-rc1, both machines are as solid
>>> as they were before it.
>>>
>> The current patch enable QoS for Hamoa SoC, which get programmed only during
>> driver probe. This shouldn't impact or cause any spurious resets once the
>> device is booted up and probe is successful.
>
> And yet it absolutely does break things.
>
> With this patch applied, the box resets within 5GB of heavy network
> traffic, probably because some transaction get delayed, and a watchdog
> fires. With the patch reverted, the box keeps receiving packets, and
> everything is hunky dory (100GB+ so far).
>
> Which makes me think that the set of hardcoded parameters in this
> patch is not universal at all.

They are, provided the configuration is for the right SoC..
Turns out Purwa has a slightly different topology and that went
unnoticed as the platform was brought up upstream.

I'll send a fix.

Konrad