Re: [PATCH 4/4] docs: iio: ade9000: document ADE9430 support

From: Jonathan Cameron

Date: Sun Sep 13 2026 - 18:20:28 EST


On Mon, 7 Sep 2026 13:16:21 +0300
Antoniu Miclaus <antoniu.miclaus@xxxxxxxxxx> wrote:

> Add the ADE9430 to the list of supported devices and note that, like the
> ADE9078, it does not provide the on-chip dip/swell voltage events. Also
> note that the ADE9430 has no on-chip digital integrator and instead uses
> an external analog integrator for Rogowski coils.
>
> Signed-off-by: Antoniu Miclaus <antoniu.miclaus@xxxxxxxxxx>
> ---
> Documentation/iio/ade9000.rst | 36 ++++++++++++++++++-----------------
> 1 file changed, 19 insertions(+), 17 deletions(-)
>
> diff --git a/Documentation/iio/ade9000.rst b/Documentation/iio/ade9000.rst
> index 72737b5ec59c..881b7ff2ad3e 100644
> --- a/Documentation/iio/ade9000.rst
> +++ b/Documentation/iio/ade9000.rst
> @@ -1,29 +1,31 @@
> .. SPDX-License-Identifier: GPL-2.0
>
> -======================
> -ADE9000/ADE9078 driver
> -======================
> +==============================
> +ADE9000/ADE9078/ADE9430 driver
> +==============================
>
> -This driver supports Analog Device's ADE9000 and ADE9078 energy measurement
> -ICs on SPI bus.
> +This driver supports Analog Device's ADE9000, ADE9078 and ADE9430 energy
> +measurement ICs on SPI bus.
>
> 1. Supported devices
> ====================
>
> * `ADE9000 <https://www.analog.com/media/en/technical-documentation/data-sheets/ADE9000.pdf>`_
> * `ADE9078 <https://www.analog.com/media/en/technical-documentation/data-sheets/ADE9078.pdf>`_
> -
> -The ADE9000 and ADE9078 are highly accurate, fully integrated, multiphase energy
> -and power quality monitoring devices. Superior analog performance and a digital
> -signal processing (DSP) core enable accurate energy monitoring over a wide
> -dynamic range. An integrated high end reference ensures low drift over
> -temperature with a combined drift of less than ±25 ppm/°C maximum for the entire
> -channel including a programmable gain amplifier (PGA) and an analog-to-digital
> -converter (ADC).
> -
> -The ADE9078 does not provide the on-chip dip/swell (sag) detection available on
> -the ADE9000, so the RMS voltage swell/dip events described below are only
> -available on the ADE9000.
> +* `ADE9430 <https://www.analog.com/media/en/technical-documentation/data-sheets/ADE9430.pdf>`_
> +
> +The ADE9000, ADE9078 and ADE9430 are highly accurate, fully integrated,

Maybe change it to

The supported parts are...

So this doesn't need updating for each new one added.

> +multiphase energy and power quality monitoring devices. Superior analog
> +performance and a digital signal processing (DSP) core enable accurate energy
> +monitoring over a wide dynamic range. An integrated high end reference ensures
> +low drift over temperature with a combined drift of less than ±25 ppm/°C maximum
> +for the entire channel including a programmable gain amplifier (PGA) and an
> +analog-to-digital converter (ADC).
> +
> +The ADE9078 and ADE9430 do not provide the on-chip dip/swell (sag) detection
> +available on the ADE9000, so the RMS voltage swell/dip events described below are
> +only available on the ADE9000. The ADE9430 additionally has no on-chip digital
> +integrator and instead uses an external analog integrator for Rogowski coils.
>
> 2. Device attributes
> ====================