Re: [PATCH v2 5/7] hwmon: sy7636a: read the temperature only while the rails are on
From: Andreas Kemnade
Date: Mon Nov 02 2026 - 05:29:12 EST
On Sun, 1 Nov 2026 19:35:16 -0800
Guenter Roeck <linux@xxxxxxxxxxxx> wrote:
> On 11/1/26 14:31, Pablo Mazzini wrote:
> > The driver enables VCOM at probe, which keeps the panel's high voltage
> > rails on for good, and gets a dummy regulator if it probes before the
> > regulator exists. Read the temperature only while the rails are on, when
> > the chip samples it, and return -ENODATA otherwise. Read power good with
> > it in one transfer, so the value can not be from before the first sample
> > or after the rails went off. Register it under the chip name, as the
> > TPS65185 and FP9931 drivers do.
> >
> > Signed-off-by: Pablo Mazzini <pmazzini@xxxxxxxxx>
> > ---
> > drivers/hwmon/sy7636a-hwmon.c | 25 ++++++++++++++-----------
> > 1 file changed, 14 insertions(+), 11 deletions(-)
> >
> > diff --git a/drivers/hwmon/sy7636a-hwmon.c b/drivers/hwmon/sy7636a-hwmon.c
> > index f01f368d68e5..475aff997c2d 100644
> > --- a/drivers/hwmon/sy7636a-hwmon.c
> > +++ b/drivers/hwmon/sy7636a-hwmon.c
> > @@ -14,7 +14,6 @@
> > #include <linux/module.h>
> > #include <linux/platform_device.h>
> > #include <linux/regmap.h>
> > -#include <linux/regulator/machine.h
> >
> > #include <linux/mfd/sy7636a.h>
> >
> > @@ -22,14 +21,22 @@ static int sy7636a_read(struct device *dev, enum hwmon_sensor_types type,
> > u32 attr, int channel, long *temp)
> > {
> > struct regmap *regmap = dev_get_drvdata(dev);
> > - int ret, reg_val;
> > -
> > - ret = regmap_read(regmap,
> > - SY7636A_REG_TERMISTOR_READOUT, ®_val);
> > + u8 buf[2];
> > + int ret;
> > +
> > + /*
> > + * Read power good and the thermistor in one transfer: the thermistor is
> > + * only sampled while the rails are on, and power good comes after the
> > + * first sample
> > + */
> > + ret = regmap_bulk_read(regmap, SY7636A_REG_FAULT_FLAG, buf, sizeof(buf));
> > if (ret)
> > return ret;
> >
> > - *temp = (s8)reg_val * 1000;
> > + if (!(buf[0] & SY7636A_FAULT_FLAG_PG))
> > + return -ENODATA;
> > +
>
> I had a look at the datasheet. It does not say anything about the
> temperature not being measured when PG is not set.
>
That is what I read from there, too. But the PG bit will only
be set if the On/Off bit is also set.
> The datasheet does suggest that temperatures are only measured
> if bit 7 of the operation mode register is set, but that is
> different from the "power good" bit in the fault register.
>
I can confirm from tests that temperature reads zero if regulator
was not yet powered on.
I read the datasheet in that way so things happen it that order:
1. on bit is set
2. ramping up voltages start / temperature sampling starts.
3. after some time (sampling time + conversion time (ADC_SPL+ADC_DEL)?),
the first sample is ready and the temperature can be read.
4. after some more time voltage lines stabilize
5. after 1.5 ms PG is asserted
> So why the association with the PG bit and not with the On/Off bit
> of the operation mode register ? That warrants some more explanation.
That should definitively be commented in the code. I have pointed out
races earlier. This has of course the drawback that it limits the time
frame in which reads are possible a bit. I doubt it is worth dealing with
synchronisation code to use that on/off bit (although posssible).
Regards,
Andreas