Re: [PATCH net-next v2 2/3] net: phy: realtek: return MDIO read errors from hwmon
From: Andrew Lunn
Date: Sat Nov 07 2026 - 12:19:05 EST
On Sat, Nov 07, 2026 at 06:00:46PM +0100, Hleb Shauchenka via B4 Relay wrote:
> From: Hleb Shauchenka <me@xxxxxxxxxx>
>
> rtl822x_hwmon_read() masks or shifts the value returned by
> phy_read_mmd() without checking it and returns success, so a failed
> MDIO read is reported as a temperature: -EIO reads as -2.5 C and
> -ETIMEDOUT as -55 C.
>
> Return the error instead. Once the sensor feeds a thermal zone, the
> thermal core then keeps its previous state rather than acting on a
> bogus reading.
>
> The problem was found by an AI review of the previous posting, and
> this patch was prepared with AI assistance (Claude Opus 5.5). It is
> build-tested only: I could not provoke a failed MDIO read on hardware.
>
> Fixes: 33700ca45b7d ("net: phy: realtek: add hwmon support for temp sensor on RTL822x")
Fixes are not wanted when targeting net-next.
You need to decide, is this a bug which bothers people, so should be
for net, have a Fixes, tag and Cc: stable. Or it is a problem which
nobody cares about, so can be in net-next as just normal development
work.
Andrew
---
pw-bot: cr