On Sat, Nov 14, 2026 at 02:20:01PM +0000, Mark Brown wrote:
> Reviewed-by: Mark Brown <broonie@xxxxxxxxxx>
>
> though we might still want a runtime override for when the user is more
> cautious.
Thank you for the review.
I agree. Looking at it again, a cautious user also has nothing to act on
today. With the warm warning masked, the warm interrupt reaches the
regulator driver with no regulator attached, so it only logs "Error IRQ
trap warm temperature". Nothing is notified.
I would rather keep this series to the board default and add the
override as a follow-up, once there is a user who needs it. I would
also change the binding text in v2, so it no longer says the operating
system decides how to react. Does that work for you, or would you like
the override in this series?