Re: [PATCH v1 4/5] dt-bindings: iio: adc: Add ADA4355
From: Marcelo Schmitt
Date: Thu Nov 19 2026 - 09:54:27 EST
Hello,
On 11/19, Jonathan Cameron wrote:
> On Wed, 18 Nov 2026 17:39:46 +0000
> Conor Dooley <conor@xxxxxxxxxx> wrote:
>
> > On Wed, Nov 18, 2026 at 10:04:13AM -0300, Marcelo Schmitt wrote:
> > > The ADA4355 is an integrated analog front-end and 14-bit analog-to-digital
> > > converter with a serial LVDS data interface.
> > >
> > > Document how to describe ADA4355 devices in device tree.
> >
> > Please explain why the 4356 differs rom the 4355 such that it cannot use
> > a fallback compatible.
>
4356 has a different set of selectable input configurations that leads to a
different scaling factor to get to milliampere units. A system with ADA4356
matching/fallingback to a device driver only supporting ADA4355 would get the
wrong _scale from the IIO device driver. Users would not be able to accurately
read data in milliampere units. ADA4355 cannot fallback to ADA4356 for the same
reason.
Will provide this explanation in v2.
> Also mention it in the patch description!
> I was briefly very confused at Conor's comment :)
>
Thanks,
Marcelo