[PATCH v11 1/2] perf vendor events: Fix misspelled keys in the event tables
From: TAKANO Mitsuhiro
Date: Fri Nov 20 2026 - 01:09:48 EST
Sixteen objects in arch/arm64/ampere/ampereonex/mmu.json carry
"PublicDescrition" and one object in each of amdzen4/cache.json,
amdzen5/load-store.json and amdzen6/load-store.json carries
"BriefDescript6ion". jevents.py reads only the keys it knows by name, so
these fields have no effect: the text is dropped without a word and never
reaches the generated tables.
For the three AMD events that leaves them with no description at all, and
the text comes back. The AmpereOneX events carry the same text in
BriefDescription and the generator drops a duplicate long description, so
the generated arm64 tables are unchanged.
This is the same change as "perf vendor events arm64 AmpereOneX: Fix
misspelled PublicDescription keys" (Message-ID
<20261113065253.746615-1-takano32@xxxxxxxxx>) and "perf vendor events amd:
Fix a misspelled JSON key" (<20261108184600.3810059-1-takano32@xxxxxxxxx>),
squashed into one patch so that this series applies on its own.
Written with Hermes Agent, an LLM assistant; the author reviewed it and
ran the generator as described.
Fixes: 16438b652b46 ("perf vendor events arm64 AmpereOneX: Add core PMU events and metrics")
Fixes: 658448281d19 ("perf vendor events amd: Add Zen 4 core events")
Fixes: 45c072f2537a ("perf vendor events amd: Add Zen 5 core events")
Fixes: 2f42fb0661d9 ("perf vendor events amd: Add Zen 6 core events")
Acked-by: Ilkka Koskinen <ilkka@xxxxxxxxxxxxxxxxxxxxxx>
Signed-off-by: TAKANO Mitsuhiro <takano32@xxxxxxxxx>
---
.../arch/arm64/ampere/ampereonex/mmu.json | 32 +++++++++----------
.../pmu-events/arch/x86/amdzen4/cache.json | 2 +-
.../arch/x86/amdzen5/load-store.json | 2 +-
.../arch/x86/amdzen6/load-store.json | 2 +-
4 files changed, 19 insertions(+), 19 deletions(-)
diff --git a/tools/perf/pmu-events/arch/arm64/ampere/ampereonex/mmu.json b/tools/perf/pmu-events/arch/arm64/ampere/ampereonex/mmu.json
index 66d83b680651..9457f9be4ecc 100644
--- a/tools/perf/pmu-events/arch/arm64/ampere/ampereonex/mmu.json
+++ b/tools/perf/pmu-events/arch/arm64/ampere/ampereonex/mmu.json
@@ -30,37 +30,37 @@
"BriefDescription": "Data TLB translation cache hit on S2L2 walk cache entry"
},
{
- "PublicDescrition": "Data TLB translation cache hit on S2L1 walk cache entry",
+ "PublicDescription": "Data TLB translation cache hit on S2L1 walk cache entry",
"EventCode": "0xd805",
"EventName": "MMU_D_TRANS_CACHE_HIT_S2L1_WALK",
"BriefDescription": "Data TLB translation cache hit on S2L1 walk cache entry"
},
{
- "PublicDescrition": "Data TLB translation cache hit on S2L0 walk cache entry",
+ "PublicDescription": "Data TLB translation cache hit on S2L0 walk cache entry",
"EventCode": "0xd806",
"EventName": "MMU_D_TRANS_CACHE_HIT_S2L0_WALK",
"BriefDescription": "Data TLB translation cache hit on S2L0 walk cache entry"
},
{
- "PublicDescrition": "Data-side S1 page walk cache lookup",
+ "PublicDescription": "Data-side S1 page walk cache lookup",
"EventCode": "0xd807",
"EventName": "MMU_D_S1_WALK_CACHE_LOOKUP",
"BriefDescription": "Data-side S1 page walk cache lookup"
},
{
- "PublicDescrition": "Data-side S1 page walk cache refill",
+ "PublicDescription": "Data-side S1 page walk cache refill",
"EventCode": "0xd808",
"EventName": "MMU_D_S1_WALK_CACHE_REFILL",
"BriefDescription": "Data-side S1 page walk cache refill"
},
{
- "PublicDescrition": "Data-side S2 page walk cache lookup",
+ "PublicDescription": "Data-side S2 page walk cache lookup",
"EventCode": "0xd809",
"EventName": "MMU_D_S2_WALK_CACHE_LOOKUP",
"BriefDescription": "Data-side S2 page walk cache lookup"
},
{
- "PublicDescrition": "Data-side S2 page walk cache refill",
+ "PublicDescription": "Data-side S2 page walk cache refill",
"EventCode": "0xd80a",
"EventName": "MMU_D_S2_WALK_CACHE_REFILL",
"BriefDescription": "Data-side S2 page walk cache refill"
@@ -90,61 +90,61 @@
"BriefDescription": "Level 2 instruction translation buffer allocation"
},
{
- "PublicDescrition": "Instruction TLB translation cache hit on S1L2 walk cache entry",
+ "PublicDescription": "Instruction TLB translation cache hit on S1L2 walk cache entry",
"EventCode": "0xd901",
"EventName": "MMU_I_TRANS_CACHE_HIT_S1L2_WALK",
"BriefDescription": "Instruction TLB translation cache hit on S1L2 walk cache entry"
},
{
- "PublicDescrition": "Instruction TLB translation cache hit on S1L1 walk cache entry",
+ "PublicDescription": "Instruction TLB translation cache hit on S1L1 walk cache entry",
"EventCode": "0xd902",
"EventName": "MMU_I_TRANS_CACHE_HIT_S1L1_WALK",
"BriefDescription": "Instruction TLB translation cache hit on S1L1 walk cache entry"
},
{
- "PublicDescrition": "Instruction TLB translation cache hit on S1L0 walk cache entry",
+ "PublicDescription": "Instruction TLB translation cache hit on S1L0 walk cache entry",
"EventCode": "0xd903",
"EventName": "MMU_I_TRANS_CACHE_HIT_S1L0_WALK",
"BriefDescription": "Instruction TLB translation cache hit on S1L0 walk cache entry"
},
{
- "PublicDescrition": "Instruction TLB translation cache hit on S2L2 walk cache entry",
+ "PublicDescription": "Instruction TLB translation cache hit on S2L2 walk cache entry",
"EventCode": "0xd904",
"EventName": "MMU_I_TRANS_CACHE_HIT_S2L2_WALK",
"BriefDescription": "Instruction TLB translation cache hit on S2L2 walk cache entry"
},
{
- "PublicDescrition": "Instruction TLB translation cache hit on S2L1 walk cache entry",
+ "PublicDescription": "Instruction TLB translation cache hit on S2L1 walk cache entry",
"EventCode": "0xd905",
"EventName": "MMU_I_TRANS_CACHE_HIT_S2L1_WALK",
"BriefDescription": "Instruction TLB translation cache hit on S2L1 walk cache entry"
},
{
- "PublicDescrition": "Instruction TLB translation cache hit on S2L0 walk cache entry",
+ "PublicDescription": "Instruction TLB translation cache hit on S2L0 walk cache entry",
"EventCode": "0xd906",
"EventName": "MMU_I_TRANS_CACHE_HIT_S2L0_WALK",
"BriefDescription": "Instruction TLB translation cache hit on S2L0 walk cache entry"
},
{
- "PublicDescrition": "Instruction-side S1 page walk cache lookup",
+ "PublicDescription": "Instruction-side S1 page walk cache lookup",
"EventCode": "0xd907",
"EventName": "MMU_I_S1_WALK_CACHE_LOOKUP",
"BriefDescription": "Instruction-side S1 page walk cache lookup"
},
{
- "PublicDescrition": "Instruction-side S1 page walk cache refill",
+ "PublicDescription": "Instruction-side S1 page walk cache refill",
"EventCode": "0xd908",
"EventName": "MMU_I_S1_WALK_CACHE_REFILL",
"BriefDescription": "Instruction-side S1 page walk cache refill"
},
{
- "PublicDescrition": "Instruction-side S2 page walk cache lookup",
+ "PublicDescription": "Instruction-side S2 page walk cache lookup",
"EventCode": "0xd909",
"EventName": "MMU_I_S2_WALK_CACHE_LOOKUP",
"BriefDescription": "Instruction-side S2 page walk cache lookup"
},
{
- "PublicDescrition": "Instruction-side S2 page walk cache refill",
+ "PublicDescription": "Instruction-side S2 page walk cache refill",
"EventCode": "0xd90a",
"EventName": "MMU_I_S2_WALK_CACHE_REFILL",
"BriefDescription": "Instruction-side S2 page walk cache refill"
diff --git a/tools/perf/pmu-events/arch/x86/amdzen4/cache.json b/tools/perf/pmu-events/arch/x86/amdzen4/cache.json
index e6d710cf3ce2..01c848a9dbb3 100644
--- a/tools/perf/pmu-events/arch/x86/amdzen4/cache.json
+++ b/tools/perf/pmu-events/arch/x86/amdzen4/cache.json
@@ -182,7 +182,7 @@
{
"EventName": "ls_inef_sw_pref.all",
"EventCode": "0x52",
- "BriefDescript6ion": "Software prefetches that did not fetch data outside of the processor core for any reason.",
+ "BriefDescription": "Software prefetches that did not fetch data outside of the processor core for any reason.",
"UMask": "0x03"
},
{
diff --git a/tools/perf/pmu-events/arch/x86/amdzen5/load-store.json b/tools/perf/pmu-events/arch/x86/amdzen5/load-store.json
index b1994539ece8..774da0bfa0dd 100644
--- a/tools/perf/pmu-events/arch/x86/amdzen5/load-store.json
+++ b/tools/perf/pmu-events/arch/x86/amdzen5/load-store.json
@@ -351,7 +351,7 @@
{
"EventName": "ls_inef_sw_pref.all",
"EventCode": "0x52",
- "BriefDescript6ion": "Software prefetches that did not fetch data outside of the processor core for any reason.",
+ "BriefDescription": "Software prefetches that did not fetch data outside of the processor core for any reason.",
"UMask": "0x03"
},
{
diff --git a/tools/perf/pmu-events/arch/x86/amdzen6/load-store.json b/tools/perf/pmu-events/arch/x86/amdzen6/load-store.json
index 4291eb59426f..4adba70bffb1 100644
--- a/tools/perf/pmu-events/arch/x86/amdzen6/load-store.json
+++ b/tools/perf/pmu-events/arch/x86/amdzen6/load-store.json
@@ -351,7 +351,7 @@
{
"EventName": "ls_inef_sw_pref.all",
"EventCode": "0x52",
- "BriefDescript6ion": "Software prefetches that did not fetch data outside of the processor core for any reason.",
+ "BriefDescription": "Software prefetches that did not fetch data outside of the processor core for any reason.",
"UMask": "0x03"
},
{
--
2.53.0