[PATCH 1/2] dt-bindings: iio: adc: adi,ad7124: make interrupts optional

From: ILYAS NHASSE via B4 Relay

Date: Fri Nov 20 2026 - 06:29:50 EST


From: ILYAS NHASSE <ilyas.nhasse@xxxxxxx>

The AD7124 signals the end of a conversion on its DOUT/RDY pin, which is
also the SPI MISO line. Using it as an interrupt requires the board to
route that pin to an interrupt-capable input as well, which is not always
possible, e.g. when the ADC sits behind a digital isolator that only
carries the SPI signals.

The end of a conversion can also be read from the RDY bit of the status
register, so the interrupt is not needed to operate the device. Drop it
from the required properties.

Signed-off-by: ILYAS NHASSE <ilyas.nhasse@xxxxxxx>
---
Documentation/devicetree/bindings/iio/adc/adi,ad7124.yaml | 1 -
1 file changed, 1 deletion(-)

diff --git a/Documentation/devicetree/bindings/iio/adc/adi,ad7124.yaml b/Documentation/devicetree/bindings/iio/adc/adi,ad7124.yaml
index 2e3f84db6..875f46477 100644
--- a/Documentation/devicetree/bindings/iio/adc/adi,ad7124.yaml
+++ b/Documentation/devicetree/bindings/iio/adc/adi,ad7124.yaml
@@ -76,7 +76,6 @@ properties:
required:
- compatible
- reg
- - interrupts

# Can't have both clock input and output at the same time.
not:

--
2.43.0