[PATCH rdma-rc] RDMA/siw: Don't send stale data for a queued zero length Read Request
From: Andrew Stellman
Date: Sun Nov 22 2026 - 14:11:35 EST
siw_init_rresp() queues an inbound RDMA Read Request in the inbound read
queue (IRQ) when the TX work request is busy. For a zero length Read
Request the IRQ entry has num_sge 0, and siw_activate_tx() then leaves
wqe->sqe.sge[0] as the previous work request left it.
siw_qp_sq_proc_tx() sets num_sge to 1 for every Read Response, so the
Read Response is built from the previous work request's sge[0]. RFC
5040, section 5.2.1, requires a zero length Read Response.
A plain TCP peer that speaks MPA rev 1 sent two Read Requests in one
write(): 64 bytes from an MR with remote read access, then a zero
length Read Request. The second Read Response carried the same 64
bytes of the MR:
Read Response, sink STag 0x11110000: 64 bytes "SIW016-REMOTE-RD..."
Read Response, sink STag 0x22220000: 64 bytes "SIW016-REMOTE-RD..."
When the zero length Read Request was sent 500 ms after the first one,
its Read Response had no payload.
Copy sge[0] from the IRQ entry whatever its length, as the immediate
path in siw_init_rresp() does. With this change the second Read
Response has no payload in both cases.
The issue was found by Claude Opus 5.5 running Quality Playbook, an
LLM-driven code review tool:
https://github.com/andrewstellman/quality-playbook
The fix and this changelog were drafted with Claude Opus 5.5 and
reviewed by me.
Fixes: f29dd55b0236 ("rdma/siw: queue pair methods")
Signed-off-by: Andrew Stellman <astellman@xxxxxxxxxxxxxxxxxxx>
---
Tested in QEMU on v7.4-rc3 with KASAN, with a plain TCP peer that speaks
MPA rev 1. A reproducer is available on request.
drivers/infiniband/sw/siw/siw_qp.c | 17 +++++++++--------
1 file changed, 9 insertions(+), 8 deletions(-)
diff --git a/drivers/infiniband/sw/siw/siw_qp.c b/drivers/infiniband/sw/siw/siw_qp.c
index bb780e3904a..f3eb1c85f3e 100644
--- a/drivers/infiniband/sw/siw/siw_qp.c
+++ b/drivers/infiniband/sw/siw/siw_qp.c
@@ -972,14 +972,15 @@ int siw_activate_tx(struct siw_qp *qp)
/* start READ RESPONSE */
wqe->sqe.opcode = SIW_OP_READ_RESPONSE;
wqe->sqe.flags = 0;
- if (irqe->num_sge) {
- wqe->sqe.num_sge = 1;
- wqe->sqe.sge[0].length = irqe->sge[0].length;
- wqe->sqe.sge[0].laddr = irqe->sge[0].laddr;
- wqe->sqe.sge[0].lkey = irqe->sge[0].lkey;
- } else {
- wqe->sqe.num_sge = 0;
- }
+ /*
+ * Copy sge[0] also for a zero length Read Request. The TX path
+ * sends sge[0] of every Read Response, and the previous work
+ * request's sge[0] must not be sent in its place.
+ */
+ wqe->sqe.num_sge = irqe->num_sge;
+ wqe->sqe.sge[0].length = irqe->sge[0].length;
+ wqe->sqe.sge[0].laddr = irqe->sge[0].laddr;
+ wqe->sqe.sge[0].lkey = irqe->sge[0].lkey;
/* Retain original RREQ's message sequence number for
* potential error reporting cases.
--
2.43.0