[PATCH net-next v3 5/7] net: phy: adin1100: Skip the soft reset on ADIN1110/ADIN2111
From: Iustin Stolniceanu
Date: Mon Nov 23 2026 - 07:00:06 EST
The ADIN1110 and ADIN2111 MAC-PHYs integrate the ADIN1100 PHY and use
this driver. On these devices, CRSM_SFT_RST resets the whole chip, not
only the PHY, undoing the configuration done by the MAC driver before
the PHY is attached. MDIO reads also return stale data until the reset
completes.
This is not an issue with the generic SPI protocol, where the adin1110
driver configures the MAC in ndo_open, after phy_connect(). The OPEN
Alliance TC6 protocol support, added in a following patch, configures
the device in oa_tc6_init() before the PHY is attached, and the
configuration would be lost.
The MAC driver already resets the chip before attaching the PHY, so
don't set .soft_reset for these devices.
Signed-off-by: Iustin Stolniceanu <iustin.stolniceanu@xxxxxxxxxx>
Reviewed-by: Alvin Šipraga <alvin.sipraga@xxxxxxxxxx>
---
drivers/net/phy/adin1100.c | 2 --
1 file changed, 2 deletions(-)
diff --git a/drivers/net/phy/adin1100.c b/drivers/net/phy/adin1100.c
index a69c3228961e..bc7214b73505 100644
--- a/drivers/net/phy/adin1100.c
+++ b/drivers/net/phy/adin1100.c
@@ -341,7 +341,6 @@ static struct phy_driver adin_driver[] = {
PHY_ID_MATCH_EXACT(PHY_ID_ADIN1110),
.name = "ADIN1110",
.get_features = adin_get_features,
- .soft_reset = adin_soft_reset,
.probe = adin_probe,
.config_aneg = adin_config_aneg,
.read_status = adin_read_status,
@@ -357,7 +356,6 @@ static struct phy_driver adin_driver[] = {
PHY_ID_MATCH_EXACT(PHY_ID_ADIN2111),
.name = "ADIN2111",
.get_features = adin_get_features,
- .soft_reset = adin_soft_reset,
.probe = adin_probe,
.config_aneg = adin_config_aneg,
.read_status = adin_read_status,
--
2.43.0