Re: [PATCH net-next v3 3/3] ionic: add devlink param for command timeout
From: Rao, Nikhil
Date: Mon Nov 23 2026 - 18:15:29 EST
On 11/22/2026 4:59 PM, netdev-bot+sashiko@xxxxxxxxxx wrote:
[...]
Doesn't that leave the user unable to see or raise cmd_timeout until theYes, a GETATTR failing at probe on firmware that supports it is rare enough that I would rather not add a separate state for it.
next FW-up or PCI reset? That would happen on exactly the slow-firmware
device this parameter is meant for. The -EOPNOTSUPP also hides the fact
that the query itself failed.
On the fw_up path, after an earlier query succeeded, the same failureIt is the value last read or set, which differs from the stored one only
leaves a stale positive value instead.
if something other than this parameter changed it, such as a firmware
update across the reset versus probe where nothing has been read yet
If the slow firmware still commits the NVM write, wouldYes, get reports the last value read or set rather than querying the firmware,
ionic_dl_cmd_timeout_get() keep reporting the old cached value while the
device holds the new one? The new value would then take effect without
notice at the next probe or reset, when ionic_update_cmd_timeout() reads
it again.
as any user can call it and a query would hold the device command mailbox.
Could a reset during that msleep() cause a NULL+offset MMIO write, or anYes, this predates the patch and affects every dev_cmd user.
access to unmapped I/O memory?
The missing serialisation between reset teardown and dev_cmd users
predates this patch.
It will be fixed separately for net.
Thanks,
Nikhil