Re: [PATCH v4 2/4] iio: magnetometer: mmc5633: Reference the datasheet for the SET/RESET wait

From: Andy Shevchenko

Date: Tue Nov 24 2026 - 03:04:04 EST


On Mon, Nov 23, 2026 at 09:26:13PM +0100, Gerard Marull-Paretas wrote:
> The 1 ms wait after a SET or RESET is tSR in the Operating Timing Diagram
> section of both datasheets. Describe it where it is defined, with the
> revision and page of each datasheet, in place of the comment at its use
> that pointed at the datasheet without either.

...

> +/*
> + * tSR, minimum time between SET or RESET and other operations, per MMC5603NJ
> + * datasheet (Rev. B, page 15) and MMC5633NJL datasheet (Rev. A, page 23),
> + * Operating Timing Diagram section.
> + */

Thanks, much better, but I would amend a formatting style a bit

/*
* tSR, minimum time between SET or RESET and other operations, per
* Operating Timing Diagram section in
* - MMC5603NJ datasheet (Rev. B, page 15)
* - MMC5633NJL datasheet (Rev. A, page 23)
*/

With that,
Reviewed-by: Andy Shevchenko <andriy.shevchenko@xxxxxxxxx>

--
With Best Regards,
Andy Shevchenko