Re: [PATCH v5 1/7] usb: dwc2: fix recovery after PM domain off

From: Fabrice Gasnier

Date: Wed Nov 25 2026 - 11:37:29 EST


On 11/24/26 22:31, Stefan Wahren wrote:
> Hi Fabrice,
>
> Am 24.11.26 um 11:52 schrieb Fabrice Gasnier:
>> On 11/21/26 21:38, Stefan Wahren wrote:
>>> Hi Fabrice,
>>>
>>> Am 17.11.26 um 18:06 schrieb Fabrice Gasnier:
>>>> When the power domain containing the DWC2 controller is disabled during
>>>> suspend, its registers are lost. Reading registers to back them up from
>>>> dwc2_suspend() after clock gating can hang STM32MP1 in both host and
>>>> device mode. Host suspend enters clock gating directly; in device mode,
>>>> this can happen if the host suspended the USB bus before system suspend.
>> Hi Stefan,
>>
>>> sorry for breaking this platform, but I only had the Raspberry Pi for testing and I didn't get much
>>> feedback last year.
>> I saw your series, sorry about that, but unfortunately I haven't tested in time...
> no worries
>>
>>> I'm not familiar with STM32MP1, could you please clarify based on the compatible which is affected?
>> Yes, "st,stm32mp15-hsotg"
> I think it would be helpful to have at least "stm32mp15" in the commit message

Hi Stefan,

This compatible is used on stm32mp15 and stm32mp13, that's why I mentioned stm32mp1.

>>
>>> Could you please explain, why backing up the registers before clock gating isn't an option?
>> Well, that can probably be an option, thanks on your suggestion!
>>
>> That's not the way I had in mind (power gating and clock gating are two things).
>> This means: prepare for register loss each time the controller is put into clock gating mode (but
>> drop the backup values when exiting clock gating without PM-wide platform suspend, as these are
>> normally not lost).
>>
>> I can rework this in V6:
>> - Add the registers backup call when entering clock gating. This will backup the registers when the
>> bus gets suspended (either as device or host), then a later PM suspend request can skip the backup,
>> if they are already backed-up.
>> - Remains some stale states, as raised by Sashiko: when doing this, most of state flags have to be
>> re-initialized. I'll try to split into separate patch to ease review.
>>
>> Is it basically what you're thinking of ?
> Yes, I'm not an expert here and mostly followed Doug's suggestions. I consider my suggestion as a
> possible fix for my original approach.
> There is a reference manual [1] for the EZR32WG ARM MCU, which also have a DWC2 IP. Even if it's not
> your SoC, the chapter 15.4.8.2 Suspend seems to have helpful information.
>
> I hope this helps.
>
> Best regards
>
> [1] - https://www.silabs.com/documents/public/reference-manuals/EZR32WG-RM.pdf

Thanks for sharing the link!

I just have sent a V6, please let me know if you have further comments there.

Best Regards,
Fabrice

>>
>> Best Regards,
>> Fabrice
>>
>>> Best regards
>