Re: [PATCH v3 7/8] thunderbolt: Decouple the waiting time of TB_PORT_UNPLUGGED and TB_PORT_UP
From: mika.westerberg@xxxxxxxxxxxxxxx
Date: Thu Nov 26 2026 - 04:22:04 EST
On Thu, Nov 26, 2026 at 08:48:54AM +0000, Chunfeng Yun (云春峰) wrote:
> On 二, 2026-11-24 at 17:00 +0100, Mika Westerberg wrote:
> > On Mon, Nov 23, 2026 at 07:36:54PM +0800, Chunfeng Yun wrote:
> > > When USB4 is woke up by device disconnect, no need wait for 2s,
> > > usually the phase2~4 takes at most about 200ms, and enters to
> >
> > usually phases 2-4 take at most..
> >
> > The 200ms is not from the spec though? It's empirical right on your
> > hardhware?
>
> Yes, you are right. The ~200ms is empirical based on testing on our
> hardware with various USB4 docks and devices, rather than a hard limit
> from the spec.
>
> In the USB4 spec, the lane adapter stays in CLd (TB_PORT_UNPLUGGED)
> throughout Phases 2-4 until it sends LT_Resume at the end of Phase 4 to
> enter Training (TB_PORT_CONNECTING), and the spec does not define an
> overall maximum timeout for Phases 2-4. At the protocol level, Phase 2
> (tConnectRx), Phase 3 (AT transactions), and Phase 4 (tLTPhase4 and
> Broadcast RT transactions) only take tens of milliseconds; in practice,
> the ~100-200ms delay mainly comes from partner router wake-up, re-timer
> initialization, etc.
>
> So I doubled that empirical ~200ms to 400ms as a safety margin.
>
> I will clarify in the commit message that this is an empirical value in
> v4. Do you think 400ms is fine here, or would you prefer 500ms to leave
> a bit more margin for active cables and older Thunderbolt switches?
This has been working fine so far so no need.