Re: [PATCH net v2 0/2] net: dsa: realtek: rtl8365mb: fix FDB lookups in VLAN-unaware bridges

From: Stijn Cleynhens

Date: Thu Nov 26 2026 - 10:50:54 EST


On Wed, 25 Nov 2026 14:13:39 +0100 Stijn Cleynhens wrote:
> - Boot: the CPU port came up and passed traffic on 6 of 6 boots,
> without the re-latch work from your v8.

A correction to this: it holds for that one unit only. A second X50-PoE,
with the same chip version 0x0050, came up with a dead CPU port on 2 of
2 boots with v14:

- the switch sends towards the SoC: s00_p06_ifOutOctets counts
(9884156 after about 20 minutes), but the SoC MAC receives nothing,
mmc_rx_framecount_gb stays at 0;
- the SoC MAC transmits (mmc_tx_framecount_gb 5606), but
s00_p06_ifInOctets stays at 0;
- the two user ports forward between themselves as usual.

That is the symptom your v8 describes for the AX55. The same unit has
run your v8 with the re-latch since early November without it, and it
came up good again when booted back into that firmware.

I put the re-latch back on top of v14, reduced to the check and the
edge: on family D, read the SDS link status once a second after
pcs_config() and, while it is clear, park the SDS_MISC mode field at
DISABLE for 20 ms and restore it, for at most 60 s. With that, the
same unit came up with a working CPU port on 10 of 10 boots; the link
bit was set after 2 or 3 edges each time.

Stijn