[PATCH net] can: mcp251x: deliver the TX echo before RX frames of the same pass

From: Nguyen Cong Thanh

Date: Sat Nov 28 2026 - 00:48:34 EST


mcp251x_can_ist() hands the frames of both receive buffers to the stack
first and returns the echo of a completed transmission only at the end
of the pass. When our frame has completed and the peer's reply is
already in a receive buffer, the reply reaches the stack before the echo
of the frame it answers. The handler returned the echo first until
commit bf66f3736a94 ("can: mcp251x: Move to threaded interrupts instead
of workqueues.") moved the receive buffers to the front of the loop.

Since commit 4b7fe92c0690 ("can: isotp: add local echo tx processing for
consecutive frames") can-isotp enters ISOTP_WAIT_FC only on the echo of
the last consecutive frame of a block, and isotp_rcv_fc() ignores a flow
control frame that arrives while the sender is still in ISOTP_SENDING.
With a non-zero block size and a peer that answers quickly, the transfer
stalls:

bus mcp251x_can_ist() can-isotp
CF 8 sent (TXIF)
FC in RXB0 (RX0IF)
read CANINTF
RX0: FC to the stack -> SENDING, FC ignored
TX: echo to the stack -> WAIT_FC
FC timeout after 1 s

Seen with an MCP2515 (SPI at 1 MHz, CAN at 500 kbit/s) on an RK3566
board talking to an STM32 bootloader that answers each block of
consecutive frames with a flow control frame (BS 8, STmin 5 ms). In
candump on the gateway the flow control frame came 0.27 ms before the
echo and the UDS download timed out. With this change, in the gateway's
candump captures of 25 downloads, all 5225 flow control frames sent
after a full block came after the echo of the frame they answer.

Return the echo whenever TXIF has been seen, before the receive buffers
that follow: at the start of the pass, and again after the CANINTF
re-read that follows RXB0, before RXB1. In the second case the frame in
RXB0 was there before our frame completed and still goes first, while a
reply that rolled over into RXB1 now comes after the echo. The MCP251x
has no RX timestamps, so the bus order of a completed transmission and
a frame received around the same time is unknown either way. A reply
can only come after our frame; the cost is that an unrelated frame
received just before it may now be delivered after the echo. The TX
block at the end of the pass only wakes the queue.

As a side effect, the echo of a completed frame is now also returned
when the pass ends in bus-off with restart-ms 0, where the loop used to
break out before the TX block.

Fixes: bf66f3736a94 ("can: mcp251x: Move to threaded interrupts instead of workqueues.")
Cc: stable@xxxxxxxxxxxxxxx
Signed-off-by: Nguyen Cong Thanh <congthanh.ml.2509@xxxxxxxxx>
---
Tested on the board above with its 6.1.57 based vendor kernel, whose
mcp251x_can_ist() is the same as in v7.4-rc4, by loading the driver
with this patch applied as a module:

- 25 UDS downloads (105 TransferData requests each) to the STM32
bootloader, all confirmed. In 20 of them, test-only counters in the
IRQ handler saw 185 passes where TXIF and an RX flag were set in the
same first CANINTF read, the window this patch is about.
- 30000 frames from cangen while the ECU sent its own frames:
tx_packets and tx_bytes grew by exactly 30000 and 240000, and 44 of
the echoes were returned by the call after the CANINTF re-read.

The RXB1 case itself (TXIF and RX1IF only in the re-read) did not occur
on this two-node bench; it comes from reading the code and the RX
rollover of the MCP2515. The bus-off path with restart-ms 0 was not
exercised. Build-tested on linux-can/main (ARCH=i386, W=1); I have not
run it on a mainline kernel. The candump logs are available if useful.

Tools: the failure showed up on my RK3566/STM32 bench, and the tests
above ran there. Claude (Anthropic) helped analyse mcp251x and can-isotp
and drafted the change and this message; an independent review with
Codex (OpenAI) found the RXB1 case, which this version handles. I have
gone through every line, checked each claim against the logs, and am
responsible for the patch.

drivers/net/can/spi/mcp251x.c | 36 +++++++++++++++++++++++++++--------
1 file changed, 28 insertions(+), 8 deletions(-)

diff --git a/drivers/net/can/spi/mcp251x.c b/drivers/net/can/spi/mcp251x.c
index 0d0190ae09..0acdab0cd0 100644
--- a/drivers/net/can/spi/mcp251x.c
+++ b/drivers/net/can/spi/mcp251x.c
@@ -1067,6 +1067,18 @@ static void mcp251x_restart_work_handler(struct work_struct *ws)
mutex_unlock(&priv->mcp_lock);
}

+static void mcp251x_tx_echo(struct mcp251x_priv *priv)
+{
+ struct net_device *net = priv->net;
+
+ if (!priv->tx_busy)
+ return;
+
+ net->stats.tx_packets++;
+ net->stats.tx_bytes += can_get_echo_skb(net, 0, NULL);
+ priv->tx_busy = false;
+}
+
static irqreturn_t mcp251x_can_ist(int irq, void *dev_id)
{
struct mcp251x_priv *priv = dev_id;
@@ -1082,6 +1094,14 @@ static irqreturn_t mcp251x_can_ist(int irq, void *dev_id)

mcp251x_read_2regs(spi, CANINTF, &intf, &eflag);

+ /* Return the echo of a completed transmission before the
+ * frames received in this pass. Without RX timestamps their
+ * bus order is unknown, but a reply to our frame, such as an
+ * ISO-TP flow control frame, can only follow it.
+ */
+ if (intf & CANINTF_TX)
+ mcp251x_tx_echo(priv);
+
/* receive buffer 0 */
if (intf & CANINTF_RX0IF) {
mcp251x_hw_rx(spi, 0);
@@ -1105,6 +1125,12 @@ static irqreturn_t mcp251x_can_ist(int irq, void *dev_id)
}
}

+ /* Our frame may have completed while RXB0 was read, with the
+ * reply rolled over into RXB1.
+ */
+ if (intf & CANINTF_TX)
+ mcp251x_tx_echo(priv);
+
/* receive buffer 1 */
if (intf & CANINTF_RX1IF) {
mcp251x_hw_rx(spi, 1);
@@ -1196,15 +1222,9 @@ static irqreturn_t mcp251x_can_ist(int irq, void *dev_id)
if (intf == 0)
break;

- if (intf & CANINTF_TX) {
- if (priv->tx_busy) {
- net->stats.tx_packets++;
- net->stats.tx_bytes += can_get_echo_skb(net, 0,
- NULL);
- priv->tx_busy = false;
- }
+ /* the echo has already been returned above */
+ if (intf & CANINTF_TX)
netif_wake_queue(net);
- }
}
mutex_unlock(&priv->mcp_lock);
return IRQ_HANDLED;

base-commit: aa40afa831ebfe45e40a23721711059f2ac584d4
--